When RFID technology is used, there are different installation requirements to consider than with RF
technology. Since the RFID field is much less strict defined than with RF technology, there is a larger area
where tags could be detected. In contrary to RF, RFID is much less sensitive to coupling or interference issues.
Automatic tag muting
The RFID reader has a maximum read throughput of around 200 tag reads per second. This throughput is used
to monitor the status of the tags continuously. When many tags are placed close to or in the label-free zone, it
might be that the reader is 'too busy' with those tags, compared to other tags. This will impact the system
performance. If this happens, the reader will mute some tags, to have time remaining for other tags. This
feature is called 
. It might therefore be that some tags in the neighborhood of the system
automatic tag muting
are muted, and will not cause an alarm when moved through the gates.
Metallic surfaces
As the RFID field is reflected by metallic surfaces, this might confuse the Dynamic Beam Steering algorithms
and influence (change or enlarge) the detection field. That is why it is advised to avoid metallic surfaces in the
neighborhood of RFID-enabled gates.