N. V. Nederlandsche Apparatenfabriek NEDAP ADRRFMD Manual Do Utilizador

Página de 59
Page 
 of 
45
59
Manual iSense Lumen series
1.  
2.  
3.  
4.  
Configuration is lost
Please note that when doing a factory reset, all settings and configuration of the unit are lost. The
firmware version does not change.
Firmware change
There are four ways to change the firmware version on a Renos-based system:
Local - single unit over-write. The over-write can be executed by inserting a USB stick with the right
firmware into the USB port.
Local - complete system over-write. The over-write can be executed during the configuration wizard
with files on your laptop.
Local - complete system update. The update can be executed during the configuration wizard with files
on your laptop.
Device Management update. The update can be executed via the Device Management service.
If the system is integrated with a 3rd party system, please confirm the firmware version with that 3rd
party before installing it.
Firmware over-write Local - single unit over-write
Download the correct firmware image file from the Nedap Retail portal. Extract this file to a USB stick. Turn off
the power of the system. Insert the USB stick in the USB port of a Renos unit. Power the system. Wait until
LEDs 4, 5 and 6 are off again. This can take around ten minutes. Then turn off the power again, remove the USB
stick and turn on the power.
Configuration is lost
Please note that when using 'local - single unit flash' firmware change, all settings and configuration
of the unit are lost.
It's only possible to execute this on-site and not remotely, as the system needs to be re-configured
before it is usable again.