13.6.6  SENSOR CALIBRATION 
To ensure reliable operation of the system the SENSIT sensors should be calibrated before 
commissioning. Calibration values can be set for the magnetic detection in each axis (x, y 
and z). Default calibration values are 50 mGauss in each axis. The default value for the IR 
sensitivity is 9, the maximum. The IR sensitivity is only lowered in case of a ceiling or other 
coverage of the SENSIT sensors. 
  
Figure 51: SENSIT sensor calibration 
SENSIT nodes can be calibrated individually. This by entering the Node ID of the specific 
sensor you want to calibrate into the field 'Calibrate node number'. 
Alternatively you can calibrate all nodes or the nodes from a specific parking lot. When you 
click 'Calibrate all nodes' all SENSIT sensors in the network will automatically be calibrated.
Click the 'Calibrate' button to start the calibration. In the menu an update message will start 
to keep you update on progress. 
 
Incorrect occupied spaces can be indicated if a vehicle parked in the neighboring parking 
space activates the magnetic sensor. If the percentage of incorrect occupied (so actually 
free) is too high over the parking lot, the magnetic values can be adjusted by selecting a 
higher value e.g. 60 mGauss. If the percentage of incorrect free (actually occupied) spaces is 
too high the sensitivity of the magnetic threshold can be reduced to lower value e.g. 40 
mGauss. 
 
13.6.7  DISPLAY 
 
Display Configuration 
The 'Display configuration' screen allows you to control a display via the node network. This 
without any physical communication wiring. Only a power supply is required. The 
communication with a display is realized via a display node. Note that this functionality is 
only available for specific displays. Contact Nedap for more information. The display node is 
part of the network and can therefore communicate wirelessly via the node network. A 
maximum number of 2 displays can be controlled in a wireless mesh network of 500 sensors. 
Use of more displays will increase the communication latency. 
 
Note 
The SENSIT nodes can only be 
calibrated when the specific 
bay and neighboring bays are 
not occupied by vehicle. When 
all SENSIT nodes need to be 
calibrated the parking lot 
must be completely empty.