SENSIT SYSTEM | MANUAL
SENSIT System
15/111
SENSIT System
2.4.3 GATEWAY EVENT BUFFER
Furthermore the Gateway is equipped with an event buffer to store up to 24k
events. This memory stores the events in case both communication means
temporary fails. As soon as the communication is restored the Gateway will transmit
the buffered events.
2.4.4 SENSIT BACKUP BATTERY
The Gateway can be completed with a backup battery to make
sure the Gateway stays alive when the mains power fails. This
backup battery can also been used when the Gateway is
powered by the public lighting pole. This cyclic use will have
an influence on the lifetime of the internal lead-acid battery.
sure the Gateway stays alive when the mains power fails. This
backup battery can also been used when the Gateway is
powered by the public lighting pole. This cyclic use will have
an influence on the lifetime of the internal lead-acid battery.
SSENSIT
BBattery
ppack
Dimensions
252 x 251 x 89 mm
(10 x 10 x 3.5 inch)
Weight
3800
gram
(134
oz)
Protection
IP65
Color
Aluminum & dark blue side covers RAL5011
Operating
temperature
temperature
-15°C … +50°C
(5°F … +122°F)
Internal battery
12VDC | 7Ah (lead-acid)
Lifetime*
>1000 discharge/charge cycles
Autonomous time**
Up to 35 hours
* Depends upon the average depth of discharge.
** Depends upon communication means 3G/Ethernet, temperature and battery age
** Depends upon communication means 3G/Ethernet, temperature and battery age
Note
By default the Gateway
event buffer is disabled. At
least version 1.6 has to be
installed at your SIS before
the event buffer function
can work.
.
By default the Gateway
event buffer is disabled. At
least version 1.6 has to be
installed at your SIS before
the event buffer function
can work.
.