2.4.3  GATEWAY EVENT BUFFER 
 
Furthermore the Gateway is equipped with an event buffer to store up to 24k 
events. This memory stores the events in case both communication means 
temporary fails. As soon as the communication is restored the Gateway will transmit 
the buffered events. 
 
 
2.4.4  SENSIT BACKUP BATTERY 
The Gateway can be completed with a backup battery to make 
sure the Gateway stays alive when the mains power fails. This 
backup battery can also been used when the Gateway is 
powered by the public lighting pole. This cyclic use will have 
an influence on the lifetime of the internal lead-acid battery. 
 
 
SSENSIT 
 
BBattery 
 
ppack 
 
Dimensions 
252 x 251 x 89 mm  
 
(10 x 10 x 3.5 inch) 
Weight 
3800 
gram 
 
  (134 
oz) 
Protection  
IP65 
Color  
 
Aluminum & dark blue side covers RAL5011 
Operating 
temperature 
-15°C … +50°C   
 
(5°F … +122°F) 
Internal battery 
12VDC | 7Ah (lead-acid) 
Lifetime* 
>1000 discharge/charge cycles 
Autonomous time** 
Up to  35 hours 
* Depends upon the average depth of discharge. 
** Depends upon communication means 3G/Ethernet, temperature and battery age 
 
 
 
Note 
By default the Gateway 
event buffer is disabled. At 
least version 1.6 has to be 
installed at your SIS before 
the event buffer function 
can work.