SENSIT SYSTEM | MANUAL 
Installation Procedures
 
 
20/111 
Installation Procedures
INSTALLATION PROCEDURES 
The installation of the SENSIT system is basically the same with or without a 
Configuration Tool and can be described in 4 major steps: The preparation, the 
installation of Gateways and Relay Nodes, the installation of SENSIT sensors and 
finally setting up the SENSIT Interface Software. 
In the next 2 paragraphs both methods are describe; with- or without the 
Configuration Tool. The functionality and used of the Configuration tool is described 
in more detail in chapter 5. 
 
4-STEPS WITHOUT THE CONFIGURATION TOOL 
 
3.1.1 
STEP 1 – PREPARATION  
a.  Arrange a scaled map of the site. 
b.  Make a site inspection to gather information: 
Draw on the map where the parking bays are located. 
Draw on the map where you can mount Relay Nodes  
Draw on the map the possible locations for the Gateway. 
c.  Make an installation plan: 
Number every parking bays with a unique number. 
Use the Relay Node Tool to plan the final Relay Node and Gateway 
locations to form a covering network. 
 
3.1.2 
STEP 2 – GATEWAY AND RELAY NODE INSTALLATION 
a.  Install and power-up the Gateway according the plan.  
b.  Activate and install the Relay Nodes according the plan. 
c.  Write the ID numbers of the Gateways and Relay Nodes at the right location 
in the plan. 
d.  Verify at the server that all Gateways and Relay Nodes are online. 
 
3.1.3 
STEP 3 – SENSIT INSTALLATION 
a.  Free the bays and close off the parking area. 
b.  Mark the right location at the road surface with a piece of chalk or paint. 
c.  Distribute the SENSIT sensors at the, to be installed locations and activate 
them with the magnet. 
d.  Make a list of the correct ID numbers and bay numbers. 
e.  Verify at the server if all SENSIT sensors come online. 
f.  Drill the holes and glue the SENSIT sensors. 
g.  Calibrate the SENSIT sensors without cars or metal tools in the 
neighborhood of the SENSIT’s. 
 
3.1.4 
STEP 4 – SETTING UP THE SENSIT INTERFACE SOFTWARE  
a.  Make a (simple) Inkscape drawing of the site based on the map and 
gathered information during STEP 1 and STEP 2. 
Draw the Relay Nodes and Gateways at the right locations 
Draw the bays at the right locations 
b.  Upload the SVG-drawing to the server. 
c.  Make a correct CSV-file and upload it to the server.  
d.  Verify if all Gateways, Relay Nodes and SENSIT sensors show up correctly in 
the system. 
 
 
Note 
There is also a planning-
tool (RelayNodeTool) 
available to plan the Relay 
Node and Data Collector 
locations. See chapter 
below for an example. 
 
 
 
 
 
 
 
 
 
 
 
 
Note 
Ask your Nedap account 
manager for special 
installation tools to 
configure, calibrate and 
register the ID to bay 
bindings. 
 
 
 
 
 
Note 
Inkscape is an open-source 
drawing program to create 
the SVG (Scalable Vector 
Graphic) drawing. 
 
 
 
 
 
 
 
 
 
 
 
Note 
Relay Node Tool is a 
planning-tool, to design the 
Relay Node and Gateway 
locations. See chapter 
below for an example. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
Note 
Inkscape is an open-source 
drawing program to create 
the SVG (Scalable Vector 
Graphic) drawing.