N. V. Nederlandsche Apparatenfabriek NEDAP SENSITGW Manual Do Utilizador

Página de 111
SENSIT SYSTEM | MANUAL 
Mounting The SENSIT Surface Mount
 
 
58/111 
Mounting The SENSIT Surface Mount
 
REPLACEMENT 
When the battery life of the SENSIT Surface Mount fails after specified lifetime, we 
advise to replace the core. The core part of the SENSIT Surface Mount is fully sealed 
and for outdoor use, therefore batteries cannot be replaced. 
 
SSENSIT Surface Mount r
r
eplacement procedure  
  
Step 1:  
Remove core 
The mounting ring can remain 
positioned in the parking space. The 
core can be unscrewed using a TORX 
screwdriver. Unscrew the core by 
opening the 4 screws in the core part of 
the SENSIT Surface Mount using a T20 
size bit screwdriver. Twist the core to lift 
up. 
 
Step 2:  
Replace core 
Place a new core into the mounting ring 
by aligning the marks on the core part 
with the marks on mounting ring as 
indicated in figure 9. Strongly push 
down the core and secure with 4 screws. 
Write down the correct ID numbers of 
the replaced core on your installation 
plan. 
 
Step 3:  
Activating 
(Segmentation) 
Calibration 
Activate the sensor, perform 
segmentation when needed and 
calibrate. Do this according the 
procedures for with or without the 
Configuration Tool as described in the 
previous chapter.  
 
SStep 4
4
::  
 
Update SIS 
Ensure to note the node ID number of 
the SENSIT Surface Mount to the parking 
bay and update the parking bay 
configuration list in the SENSIT Interface 
Software (SIS), see chapter 17.8.2 
 
 
 
 
 
 
Note 
Once out of the 
transport/stock mode the 
battery lifetime starts to 
count. 
 
Note 
Also ensure not metal parts 
(such as tools) aren’t 
positioned in the 
surrounding of the sensors 
as this might affect 
calibration.