TRANSIT ULTIMATE | INSTALLATION GUIDE 
LED INDICATIONS
 
 
26/33 
5.
  LED INDICATIONS 
5.1
  MAIN BOARD INDICATIONS 
A number of LEDs on the main board of the TRANSIT Ultimate indicate the status of 
the reader. The list below describes the function of each LED. 
 
Figure 21: LED indications main board 
 
Led 
Description 
 RX_LEVEL  LED bar indicating the received microwave tag signal strength. This 
LED bar may also indicate the presence of radio interference. In 
case of interference, try switching to a different frequency. See 
chapter 4.5. 
 
 SQ-EN 
Squelch enabled. See chapter 
4.6. 
 SQ-ACT 
Squelch active. See chapter 
4.6. 
 
 INPUT-1 
Input 1 status. On when contact is closed. See chapter 3.4.4. 
 INPUT-2 
Input 2 status. On when contact is closed. 
 INPUT-3 
Input 3 status. On when contact is closed. 
 
 Tx 
Transmit serial data (USB, I/F-board). See chapter 4.2. 
 Rx 
Receive serial data (USB, I/F-board). 
 
 STS-LED 
TRANSIT firmware status LED (PIC) 
Slow blinking: 
Heartbeat (0.8s on / 0.8s off) 
Fast blinking: 
Boot loader active. Indicated after restart. 
Twice blinking:  Configuration menu active. 
Off: 
Abnormal situation. 
 ID-LED 
TRANSIT identification. Blinks fast upon valid tag. 
When no identification check dip-switches and customer-code. 
 
 FAIL-XV5P 
Power supply failure +5V. 
 FAIL-XV15P 
Power supply failure +15V. 
 FAIL-XV15N 
Power supply failure -15V. 
 FAIL-DC_MAIN  Power supply failure DC-MAIN. 
 FAIL-Temp 
Temperature critically high. 
 FAIL-DC_OUT  DC OUTPUT overload. See chapter 3.2.3. 
 
 Unlocked 
PLL unlocked. Check flat cables to transceiver board. Try switching 
to a different frequency. See chapter 4.5. 
 
 Read disable  Read Disable LED. On while reading disabled. See chapter 3.4.2. 
 
 
 
 