3.2.2  MA4011D (and/or MA4012D) Power/Control Module Modes
ADDRESS
When this mode is selected, the display will read: Address XXX
*
The displayed address is the currently selected MA4002D Chassis Address. A different
address can be selected by pressing the UP/DOWN buttons. The MA4002D chassis has an
address from 001 - 999. The address is only used for remote control and monitoring purposes.
The factory default address is 999.
RS232/RS485/TERMINL SELECT
When this mode is selected, the display will read: RS232 Selected
or
RS485 Selected
or
Terminl Selected
Pressing the UP/DOWN buttons will toggle the display between RS232, RS485 and Terminal.
*
The Remote Interface Connector Pinout will change depending upon the Interface Type
selected. Please refer to Section 4.2, Power/Control Module Rear Panel Connection (pp 21,
22) for details.
*
When the SNMP option is installed, the user can also select the SNMP Interface in this mode.
3.3  Remote Control Operating Instructions
The MA4000 system may be controlled via the RS232/RS485 Remote Interface connector. (Refer to Section 4.2,
Power/Control Module Rear Panel Connections (pp 21, 22) for the connector pin-out).
The input data rate can be 9600, 14400, or 28800 baud. The system controller will automatically determine which
data rate is in use and adjust accordingly. There are no user settings relating to baud rate selection.
For additional information refer to Section 7.0, Detailed Remote Control (pp 27 to 34).