Embed International Pty Ltd STS001 Manual Do Utilizador

Página de 14
 
 
www.embedcard.com 
 
10 
 
 
If +12 v DC is not available from the game or is unstable then you will need to install a dedicated 
+12v DC 1000mA supply. Note: it’s very important the DC Ground of the new power supply is 
commoned  with  the  existing  DC  Ground  of  the  existing  in  game  power  supply.  Without  this 
common ground ant ticket or coin monitoring will not operate correctly.  
 
Game Credit Connections 
 
Pin number 
Wire Colour 
Wire Function 
ORANGE/BLACK  CREDIT 1 N.O. 
YELLOW/BLACK  CREDIT 1 COM. 
 
Note “N.O. means “Normally Open”, “COM.” Means “Common” 
 
On  the  selected  player  station  you  can  typically  disconnect  the  common  and  normally  open 
connectors  from  the  existing  coin  switch  and  plug  them  directly  into  the  pre  fitted  harness 
connectors.  
 
Connect the other end of the harness to the smartTouch Swipe at connector J7.