Rothenbuhler Engineering Company Inc 1673-1 Manual Do Utilizador

Página de 68
1673 OPERATION MANUAL REV A 
Item 
Item Name 
Description 
ELECTRONIC KEY PORT 
Electronic key must be installed to Arm and Fire Remote units.   
LIQUID CRYSTAL DISPLAY 
The LCD displays information to the user such as battery charge, operation mode, etc. Backlights when switches are pressed. 
KEYPAD AREA 
24 switches used to control the unit through various modes of operation. 
CHARGE/PROGRAM PORT 
Used to supply power to the internal charger and provides a serial connection for reading the history log and changing settings. 
SYSTEM INDICATORS 
Displays information related to system operation. 
POWER LIGHT 
Solid yellow indicates the unit is on. Flashes yellow to indicate the battery must be recharged. 
KEY LIGHT 
Solid yellow indicates the correctly programmed Controller key is installed and working. Flashes when a faulty or incorrect key is 
installed. 
TX LIGHT 
Lights red when unit is transmitting. 
RX LIGHT 
Lights green to indicate an on channel carrier or when receiving a message from a Remote unit. 
10 
BATTERY CHARGER INDICATORS 
Displays battery charging status. 
11 
FAST CHARGING LIGHT 
Lights red to indicate the battery is being fast charged. Blinks red when charge is pending. 
12 
SLOW CHARGING LIGHT 
Lights green to indicate battery charging is complete and the battery is receiving a slow maintenance charge. Blinks green to indicate a 
charging error has occurred. 
13 
INFORMATION LABEL 
Shows model number, serial number, system number, and regulatory information. 
14 
DISARM SWITCH 
When pressed, sends a Disarm command to all selected Remote Units. 
15 
ARM SWITCH 
When pressed and held for ½ second, sends the Arm command to all selected Remote Units. 
16 
MENU SWITCH 
Brings up the main menu screen, or returns to the default screen. 
17 
OFF SWITCH 
Turns power off to the unit when not in use or when charging. 
18 
BATTERY TEST SWITCH 
Pressing causes a 10 second loaded battery test. Holding for 5 seconds causes unit to discharge the battery completely for long term 
storage and battery conditioning. 
19 
ON SWITCH 
Turns power on to the unit. 
20 
STATUS SWITCH 
Requests status response from Remote Units.   
21 
SELECT SWITCH 
Pressing once allows up to 8 Remote Units to be selected with switches (1-8). Pressing a second time locks the selection into the unit. 
22 
NUMERIC SWITCHES (x10) 
Used for selection of Remote units and various menu options and settings. 
23 
FIRE SWITCH (x2) 
When both FIRE switches are pressed and held simultaneously for ½ second, all Remote Units that are both selected and armed will 
be fired. 
24 
REMOTE READY LIGHT (x8) 
Lights solid green to indicate the corresponding Remote Unit’s status is confirmed disarmed. Blinks green to indicate the corresponding 
Remote Unit’s status is assumed to be disarmed (unconfirmed). 
25 
REMOTE BATTERY LIGHT (x8) 
Lights solid yellow after receiving a status response from a corresponding Remote whose battery is ok. Blinks yellow to indicate the 
corresponding Remote unit has a low battery and should be recharged. 
26 
REMOTE SELECT LIGHT (x8) 
Lights yellow to indicate the corresponding Remote Unit has been selected for communications with the Controller. 
27 
REMOTE ARMED LIGHT (x8) 
Solid red indicates the corresponding Remote Unit is confirmed to be armed. Blinks red when the corresponding Remote unit is 
assumed to be armed but has not been confirmed as armed. 
28 
REMOTE UNIT DISPLAY AREA 
Displays basic information related to the operation of up to 8 Remote Units. 
Table 2-2 Controller Unit