Checkpoint Systems Inc. EVOLVEM Manual Do Utilizador

Página de 1
Federal Communications Commission Statement
WARNING!
This device complies with part 15 of the FCC Rules and RSS-210 of the Canadian Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note> This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may course harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
--Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
FCC ID: S8OMEDET3420 and S8OMEDET3480 - IC ID: 5849A-MEDET3420 and IC ID: 5849A-MEDET3480
User’s Manual
Article number: 90310901
11
Large detector area like an EAS antenna
Small detector area like the PlexPost detector
Narrow distance between the detectors (less than 1.2 - 1.4 meter)
Wide distance between the detectors (greater than 1.2 - 1.4 meter)
Detector size adjustment preset 2
Detector size adjustment preset 1
High metal sensitivity
Normal metal sensitivity
AM filter OFF
AM filter ON
1 ON
1 OFF
2 ON
2 OFF
3 ON
3 OFF
4 ON
4 OFF
5 ON
5 OFF
S1
Master
Slave
TX2 OFF
TX2 ON
TX2 in phase with TX1
TX2 opposite phase with TX1
Received signal in phase with TX1
Received signal opposite phase with TX1
TX1 OFF
TX1 ON
1 ON
1 OFF
TX1 in phase with TX sync (only when slave)
TX1 opposite phase with TX sync (only when slave)
4 ON
4 OFF
5 ON
5 OFF
6 ON
6 OFF
7 ON
7 OFF
8 ON
8 OFF
S2
S3
Select Alarm accept time window (ATW) in Advance mode
Select Alarm accept time window (ATW) in Advance mode
Select Alarm accept time window (ATW) in Advance mode
Select Alarm accept time window (ATW) in Advance mode
Trolley rejection disabled
Trolley rejection enabled
Simple detection
Advance detection (Receiver phase = Red flash(ANT SIZE))
1 ON
1 OFF
2 ON
2 OFF
3 ON
3 OFF
4 ON
4 OFF
1
2
3
Moving door
Radar
Radar detection zones
0
Accept Time Window (ATW) for
passing the gate
in
out
S3 Selection
Function
Simple /
Trolley
Accept
advance
off/on
ATW
ATW
Type of
Time
Moving door radar
S3 (1)
S3 (2)
S3 (3) S3 (4)
detection
Window
Alarm delay
Use when
detection zone
OFF
OFF
Simple
0.1 sec
No moving door
OFF
ON
Simple
1 sec
No moving door + Trolley
ON
OFF
OFF
OFF
Advance
0.65 sec
0.1 sec
Moving door
0
ON
OFF
ON
OFF
Advance
1.3 sec
0.1 sec
Moving door (standard setting)
1
ON
OFF
OFF
ON
Advance
2.6 sec
0.1 sec
Moving door
2+3
ON
OFF
ON
ON
Advance
2.6 sec
0.1 sec
Moving door
2+3
ON
ON
OFF
OFF
Advance
0.65 sec
1 sec
Moving door + Trolley
0
ON
ON
ON
OFF
Advance
1.3 sec
1 sec
Moving door + Trolley
1
ON
ON
OFF
ON
Advance
2.6 sec
1 sec
Moving door + Trolley
2
ON
ON
ON
ON
Advance
2.6 sec
2 sec
Moving door + Trolley
3
Alarm time = 4 sec
Alarm time = 8 sec
2 ON
2 OFF
Extern Alarm reset OFF (Spare in)
Extern Alarm reset ON (Spare in)
3 ON
3 OFF