Ritron RIT17-442 Manual Do Utilizador

Página de 17
 
 
1)  Select a channel. 
2)  Adjust squelch pot R144 fully counter clockwise. 
3)  Adjust the communications test set generator on frequency with an output level of –120dBm. The deviation 
should be +/- 1.5 with a 1 kHz audio signal. 
4)  Slowly adjust squelch pot R144 clockwise until squelch opens. 
5)  Reduce generator level until radio squelches. 
6)  Increase generator level until audio opens.  Confirm squelch hysteresis is between 0.5 and 5 dB. 
 
 
16