Ritron RIT44-465 Manual Do Utilizador

Página de 19
16 
 
 
RX SMB connector  RX BPF tuning caps 
TP101  RX VCO C150  TP102  4 Amp fuse 
 
 
 
 
TX SMB connector 
RF power adj C206 
TX VCO C296  TP201  J308 
 
6. 
FACTORY ALIGNMENT 
 
6.1 
DUPLEXER 
 
Tuning the duplexer requires either a network analyzer or an accurate RF signal generator and low level RF 
detector. If the customer uses a repeater transmit frequency that is lower than the receive frequency the 
coaxial cable connections are direct. That is to say, the transmit duplexer cavities are directly below the 
transmitter and the receive duplexer cavities are below the receiver section. Otherwise the cables will cross 
each other when connected to the RF board. 
 
1)  Disconnect power from the repeater. Disconnect SMB coaxial connectors from the RF board. 
Inserting a flat screw drive between the connector parts and twisting will aid in releasing the cable. 
Do not pull on the cable base as this could damage the cable. Connect SMB adapters and coaxial 
cables to test instrument. If desired test equipment can go through both duplexers at once. This 
will produce notches at two frequencies 5 MHz apart. 
2)  To adjust transmit duplexer to notch receive frequency where TX frequency is below RX 
frequency, set or look at response at receive frequency. Adjust screws under transmitter to 
minimize response at RX frequency.