Harris Corporation RF Communications Division RF-7800W-G2 Manual Do Utilizador

Página de 117
5-2
RF-7800W
TROUBLESHOOTING AND MAINTENANCE
R
NOTE
The Telnet session must connect to the RF-7800W HCLOS 
Radio within approximately 20 seconds from when the radio 
starts responding to pings. Logging into the default IP Address 
will cause the unit to be reset to the factory default 
configuration.
i.
Enter the following to log in:
1.
User Name - type admin and press [Enter].
2.
Password - type admin and press [Enter]. The password characters do not echo to the computer 
screen.
j.
Enter the command save defaultconfig and press [Enter] to ensure that all parameters are set to default 
values.
k.
Enter the following commands to set a new IP address. A 192.168.26.2# prompt is shown at each step.
1.
set ipaddr <IP Address> followed by [Enter]
Note the spaces in this example: set ipaddr 192.168.100.1
2.
save config followed by [Enter]. A message such as, “Connection to host lost.” will display.
l.
Log in to the new IP address and use the user command to enter new user name and password 
information, if required.
Figure 5-1. Factory Default Reset Time Frame
CL-0426-4200-0020
POWER OFF 
6 TO 8  
SECONDS
POWER ON 
GREATER THAN
3  MINUTES
POWER ON APPROX. 
2 MINUTES 40 SECONDS
AND BEGIN
 TELNET SESSION