MasterCard® PayPass™ Contactless Transit Pilots 
Installation Guide 
 
NOTE PLEASE ENSURE THAT THE POWER CABLE IS NOT PLUGGED INTO THE 3-PIN 
SOCKET BEFORE THE NEXT STEP. 
4.
 
Attach LAN cable [6] to the connection point in the turnstile.  
5.
 
Rest the Secura on the top of the turnstile. 
6.
 
Attach the Secura Control Unit Assembly [2] to the LED Indicator Board Cable [5] as 
shown above. 
7.
 
Attach  the  Secura  Control  Unit  Assembly  [2]  to  Secura  to  Contactless  Reader  Cable 
[4] as shown above. 
8.
 
Attach the Secura Control Unit Assembly [2] to the LAN cable [6] as shown above. 
9.
 
Attach the Secura Control Unit Assembly [2] to Solenoid cable [7] 
10.
 
Ensure that all connection points are fully home. 
11.
 
With  the  Secura  still  resting  on  the  top  of  the  turnstile,  plug  in  the  power  and 
ensure that the Secura powers up correctly and the LEDS light up. The Secura display 
will display a couple of events, namely: 
o
 
Event 20 – power up 
o
 
Event 23 – In Service 
16.
 
The terminal may attempt to contact MMS at this point, to pick up its configuration. 
This will take a few moments to complete. 
17.
 
A number  of  self-tests can then be  carried out using  the key board  functions of the 
Secura. Refer to section 5 for full details of the available functions. 
a)
 
Select function 37 on the keyboard, press 3, 7 then ENT. This will switch on 
the green LEDs 
b)
 
Select function 38 on the keyboard, press 3, 8 then ENT. This will switch on 
the green LEDs 
c)
 
Select  function  26  on  the  keyboard,  press  2,  6  then  ENT.  This  will  exercise 
the green LEDs, the red LEDS and fire a turnstile release (solenoid) pulse. 
d)
 
If  the  terminal  has  not  contacted  MMS  when  power  was  applied,  perform  a 
communications test to ensure that connectivity with MMS can be established 
satisfactorily. Do this by selecting function 46. 
e)
 
Test  that  communications  with  the  Transit  Payment  Platform  Authorisation 
Server can be established by performing function 44. 
f)
 
Test  that  communications  with  the  Transit  Payment  Platform  Batch  Server 
can be established by performing function 45. 
g)
 
Ensure  that  the  terminal  is  taken  out  of  diagnostic  mode  by  performing 
function 10. 
h)
 
Other  available  test  functions  can  be  performed  –  refer  to  section  5  for  full 
details of the available functions. 
18.
 
Remove power by unplugging the 3-Pin plug. 
19.
 
Position  the  Secura  into  the  body  of  the  turnstile  ensuring  that  the  cables  are  not 
trapped or likely to be stretched when positioning the Secura into its bracket.