Environmental Capabilities
Table 11
Environmental Parameters
Unit
Value
Vibration sinus:
displacement
mm
0.6
acceleration
m/s²
2
frequency
Hz
2 - 9
9 - 200
no. of sweep cycles
5
no. of test directions
3
testing method
IEC 68-2-6
Vibration random:
ASD
m
2
/s
3
0.1
1)
ASD
m
2
/s
3
0.2
2)
acceleration
m/s²
3.8
1)
acceleration
m/s²
5.4
2)
frequency
Hz
2 - 200
testing method
IEC 68-2-64
Shock:
< 100 kg
> 100 kg
peak acceleration
m/s²
250
100
3)
duration
ms
6
6
pulse shape
half sine
no. of shock pulses
500 per
direction
no. of test directions
6
testing method
IEC 68-2-27
1)
Safe function
2)
Non-destruction
3)
These requirements belong to the Safe function with one exemption:
performance of the RBS shall be verified as "no loss of calls".
Seismic Exposure
The complete equipped RBS shall be tested for seismic exposure.
Deviations shall be reported.
Safe function during seismic exposure. Deviations shall be reported.
Table 12
Test frequency range
1 - 15 Hz
Required Response Spectrum
RRS
Shape of RRS
as IEC fig 3
Number of time scale histories
1/ testing direction
Duration of time scale histories
35 s
Number of testing directions
3
EN/LZT 720 0024
R2A
2002-11-01
23 (34)
© Ericsson Radio Systems AB
— All Rights Reserved —