Site Planning and Product Data
Power Consumption
Power consumption: <83 VA.
AC Mains Connection
Type of connection: Clamp terminal 2 x max. 2.5 mm
2
, and screw
terminal used for protective earth.
Cable gland capacity:
16 mm.
Max 2,5 mm
2
P004799A
16 mm
AC
Figure 15
AC Mains Limiting Values
Table 1
AC mains limiting values
Frequency
Short circuit current
Inrush current/phase
(typical 10 ms)
50 Hz
max. 50 A
< 5 kA
60 Hz
max. 60 A
< 5 kA
3.2.3
Transmission
Transmission Cables
RBS 2401 can be connected to transmission interface G.703 type E1,
using two coaxial cables 75
 or four-wire twisted pair 120  .
LZN 302 14
P3A-1
1999-11-10