2.5.1 Local Control PCB
SLP10016 – Local Control
The Optional Local Control can be used as either a local or remote operating panel. The Local
Control is a microprocessor-based (Motorola M68HC11) unit offering partial control over the
controller / monitor and thereby the system. It offers similar functionality to a standard front
panel on older equipment.
Control is a microprocessor-based (Motorola M68HC11) unit offering partial control over the
controller / monitor and thereby the system. It offers similar functionality to a standard front
panel on older equipment.
Pushbuttons allow the user to select and or control the following:
Primary Transmitter Select (1 or 2)
Mode Select (ID, CONT or CARR)
Transmitter Displayed (1 or 2)
Mode Select (ID, CONT or CARR)
Transmitter Displayed (1 or 2)
And view readings of: readings for:
PA Voltage
PA Current
PA Temperature
Forward Power
Reflected Power
Modulation%
Audio Frequency (tone)
RF Frequency
PA Current
PA Temperature
Forward Power
Reflected Power
Modulation%
Audio Frequency (tone)
RF Frequency
The user can adjust or set the:
Modulation Percentage
RF Power output level
RF ON/OFF
Enable/Disable Alarms
Select Local/Remote Control
RF Power output level
RF ON/OFF
Enable/Disable Alarms
Select Local/Remote Control
When one of any pushbuttons is pressed except RESET, the 6811 processor sends a data
command to the Controller / Monitor through the serial communication port.
RESET forces Local Panel re-initialization.
RESET forces Local Panel re-initialization.
The 7 segment led display update comes from the Controller / Monitor The displays provide the
3 following groups for reading:
3 following groups for reading:
1. RF Power:
Up to 4 digits display the Modulation%, forward power and reflected power.
2. Power Amplifier (P.A.):
Up to 3 digits Display the voltage, current and temperature.