Mobilaris AB 466B Manual Do Utilizador

Página de 4
 
 
 
User Manual: 
Mobilaris long-life personnel tag  
Mobilaris offers a set of various WiFi tags that enables 
localization of personnel and mobile equipment (such 
as vehicles or machinery) within the WiFi network. 
These tags transmit a beacon signal (in CCX blink 
mode, including the MAC address of the tag) in certain 
intervals to the WiFi access points network. Using 
special algorithms, the information is used to 
determine the position of each tag. 
 
  
Inside of a network where the Mobilaris Mining 
Intelligence (MMI) system is not enabled, the tag will 
continue to function as a standard WiFi tag, sending 
out CCX blink signals at a defined standard interval or 
at a factory configured interval.  
 
If a tag is used within a network that supports the 
Mobilaris Mining Intelligence system, more 
functionality is enabled: 
•  Tags can be automatically updated over the air 
(OTA) with software updates or new configuration 
(such as blink rates, sleep times, IP address of the 
receiving MMI etc). 
•  The Tag can be configured to communicate with 
MMI when the tag is near an exciter (in order to 
increase accuracy or to open a gate or similar). 
•  Personnel tags can be configured to communicate 
with MMI when the user has pressed a dedicated 
button on the tag. 
 
 
 
 
The long-life personnel tag is equipped with a 
powerful battery with a life cycle of up to three years 
(depending on transmission rates and other 
configurable parameters). 
The tag has the following additional functionalities: 
•  Two multi-functional push-buttons (P1 and P2). 
•  A LED light indicator that provides specific 
indications but can also be customized for various 
indications. 
•  An additional antenna that can sense an optional 
exciter (magnetic bubble) and trigger extra 
beacons and MTP Updates sent up to MMI. 
•  A battery saving mechanism that can put the tag 
into sleep mode by decreasing the blink rate and 
by that increasing the battery time. This happens if 
the tag has not been moving during a configurable 
amount of time. 
Using the Mobilaris Mining Intelligence system, the 
tag can be configurated and its firmware can be 
updated over the air (OTA). This can also be explicitly 
achieved by a short press of the P2 button in normal 
state or automatically over a configurable period of 
time (i.e. every few hours/days). 
In the unusual use case where a person configures a 
tag erroneously so that the tag cannot reach the MMI 
or the OTA server, there are procedures to get it back 
to life: 
•  If a tag cannot connect to the MMI system, a 
preconfigured fall-back OTA server can be utilized 
by a long-press on the P2 button. 
•  If the P1 and P2 buttons are being pressed 
together for 10 seconds, the tag is forced into a 
hardware reset. 
Using the push-buttons or the battery saving 
mechanism, the tag can switch between three 
different states as described to the right: