Bosch Thermotechnik GmbH CT200 Manual Do Utilizador

Página de 13
Assembly
 
EasyControl – 6720884199 (2018/01)
4
3.9
Proximity sensor and touch screen
Fig. 2
Proximity sensor and touch screen
[1]
Proximity sensor
[2]
Touch screen
A proximity sensor [1] detects a presence in front of the touch screen 
[2] and lights up. If nothing more is detected for a short period of time, 
the touch screen automatically switches off. If the detection lasts for 
longer than 5 minutes, the touch screen automatically switches off. After 
this, the touch screen can only be activated again by touching it.
▶ If required, clean the touch screen with a clean, dry cloth.
4
Assembly
4.1
Prior to installation
▶ Prior to installation, check that EasyControl can be combined with 
the heat source.
On the EasyControl site there is a list of possible combinations with or 
without the operation of the EasyControl.
1)
Minimum requirements for installation:
▶ 2-wire cable to a heat source, which is suitable for use with 
EasyControl.
▶ Broadband internet access via Wi-Fi 802.11 b/g (2.4 GHz) for use 
with the app and internet functions.
4.2
Determining the installation location
A reference room is a room (for example the living room), where the 
temperature, which is representative of the whole dwelling, is measured, 
and where most time is spent.
If weather-compensated control is used, it is not necessary to locate the 
controller in the reference room.
▶ Install the controller on an internal wall in the reference room. Ensure 
that there is sufficient clearance around the controller.
Fig. 3
Installation location for controller, clearance
Fig. 4
Installation location for controller, condition
4.3
Fitting the wall plate
When replacing a controller of the 100 to 400 series with EasyControl, 
the existing wall plate can continue to be used (
This wall plate can be fastened directly to the wall, for example at the 
location of the previous controller.
▶ Pull the mains plug of the heat source from the socket.
When fitting to a recessed wall box, ensure that the room temperature 
measurement can not be impaired by any draughts. If required, stuff the 
recessed wall box with thermal insulation material.
▶ Connect the lead (EMS-BUS connection of the heat source) to the 
terminals on the wall plate. The wires can be connected in any order.
Fig. 5
Connecting the wall plate
1) See the back of this document for the web address.
0010018148-001
1
2
0010018149-001
1,2 - 1,9 m
≥ 0,75 m
≥ 1 m
≥ 0,6 m
0010018150-001
≥ 1 m
≥ 0,4 m
≥ 0,6 m
0010018151-002
EMS
l     100 m
EMS BUS