3 Specifications
3.1 General
Item
Specification
Descriptions
Size
59.8(W) x 83.3(H) x 24.6(D)
Unit : mm
Weight
78 grams
Operating Temperature
-30℃ ~ +70℃
Storage Temperature
-40℃ ~ +85℃
Vibration
Random 5~20Hz 0.05g2/Hz, 20~150Hz: -
3dB/oct.(1.7g rms), 3-axis, 30minutes
for each axis.
3dB/oct.(1.7g rms), 3-axis, 30minutes
for each axis.
Thermal Shock
-40℃ (1H)/+85℃(1H), 1cycle- Total24
cycle, 48H, non-operating
cycle, 48H, non-operating
Humidity
+70℃/95%/48 Hours, Operating
Input rating
12 Vdc - 24 Vd.c, 1 A
3.2 Communication
Item
Specification
Descriptions
Communication
- UART(RS-232)
I/O
- 6 Pin
Waterproof
LED
- 3 LEDs
Power, OK, FAIL
Buzzer
-
Level: Min. 90.0dB
3.3 Accessories
Item
Specification
Descriptions
NFC Card
NFC - A
(ISO/IEC14443A)
NFC
– B/F type