OMESH Networks Inc. OPM15E1 Manual Do Utilizador

Página de 24
www.omeshnet.com
 
 
Tel:
 
1-416-837-8980
 
• 
Fax:
 
1-416-977-2796
 
 
Email:
 
info@omeshnet.com 
OMESH
 
Networks Inc. © 2011
 
 
2
#define COMMAND_SETPOWER     
 
0x08 
#define COMMAND_READRX        
 
0x09 
#define COMMAND_READSTA 
 
 
0x0D 
#define COMMAND_RESETSTA   
 
0x0E 
#define COMMAND_CLEARAD   
 
0x0F 
#define COMMAND_SETPASSCODE      
0x10 
#define COMMAND_SETRETRYLIM        
0x11 
#define COMMAND_GETVERSION 
 
0x12 
#define COMMAND_GETPASSCODE 
 
0x13 
#define COMMAND_SETMESHADDR 
 
0x14 
#define COMMAND_GETMESHADDR   
0x15 
#define COMMAND_SETMACADDR 
 
0x16 
#define COMMAND_GETMACADDR 
 
0x17 
#define COMMAND_GETDEVICEID 
 
0x18 
#define COMMAND_RADIOTEST  
 
0x1A 
#define COMMAND_STOPTEST   
 
0x1B 
#define COMMAND_READPOWER 
 
0x1C 
#define COMMAND_GETRETRYLIM 
 
0x1D 
#define COMMAND_POWERSAVEON   
0x1E 
#define COMMAND_POWERSAVEOFF   
0x1F 
#define COMMAND_QUERY                       
0x20 
#define COMMAND_QUERYCONF            
0x21 
#define COMMAND_SETINTLEV   
 
0x22 
#define COMMAND_READINTLEV 
 
0x23 
#define COMMAND_SETBAUD   
 
0x24 
#define COMMAND_READCONF   
 
0x25 
#define COMMAND_SETROUTELIM        
0x26 
#define COMMAND_GETROUTELIM        
0x27 
#define COMMAND_MBROADCAST         
0x28 
#define COMMAND_CALIBRATE       
 
0x29 
#define COMMAND_READQUERYCONF 
0x2A 
#define RSP_SUCCESS           
 
 
0x80 
#define RSP_FAIL               
 
 
0x00 
#define EVENT_RESET          
 
 
0x0A 
#define EVENT_WAKEUP         
 
 
0x0C 
 
Section 3: Commands and Events 
 
3.1  Command RESET  
Write COMMAND_RESET (0x00) to the serial interface of the Module. The Module will 
return a RSP_SUCCESS | COMMAND_RESET (0x80). The command always has a 
successful response.