ICOM 301500 Manual Do Utilizador

Página de 102
58
6
FUNCTIONS FOR TRANSMIT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
N Split frequency operation
Split frequency operation allows you to transmit and 
receive in the same mode on two different frequen-
cies. The split frequency operation is performed using 
2 frequencies in VFO A and VFO B.
  The transmit and receive frequencies must be in 
the same band
The following is an example of setting 7.0620 MHz for 
receiving and 7.0750 MHz for transmitting.
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P.AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[DIAL]
[M-CH]
F-INP ENT
BAND
A/B
2
=
3.5
SPLIT
3
7
Keypad
q Push 
A/B
=
 to select VFO A.
w  Set the frequency to 7.0620 MHz and mode to 
LSB. (pgs. 25, 29)
e Push 
SPLIT
 to turn the split function ON.
 • 
” appears on the LCD.
Appears
r  Push and hold 
A/B
=
 for 1 sec. to equalize the un-
displayed VFO B frequency and operating mode 
with the displayed VFO A.
t Push 
A/B
=
 to select the VFO B.
y Set the frequency to 7.0750 MHz (LSB). (p. 25)
u Push 
A/B
=
 to return to the VFO A.
i  Now you can receive on 7.0620 MHz and transmit 
on 7.0750 MHz.
 To swap the transmit and receive frequencies, 
push 
A/B
=
 to exchange the VFO A and VFO B.
 CONVENIENT!
M QUICK SPLIT FUNCTION (p. 59)
When you push and hold 
SPLIT
 for 1 sec., the split 
function is activated, and the undisplayed VFO is set 
the same as the displayed VFO. (This operation is 
same as the steps 
e and r as at left.)
This shortens the time needed to start split fre-
quency operation.
Quick split function is turned ON by default but can 
be turned OFF in the set mode (p. 76).
M XFC FUNCTION (p. 76)
When the XFC (transmit frequency check) function 
is ON, the transmit frequency can be changed (this 
operation is same as the steps 
t and y as at left.)
  NOTE: When the XFC function is ON, the RIT cal-
culation function (p. 44) is not available.
q  Set the XFC (transmit frequency check) function 
ON in the set mode.
q  Push and hold 
M-CH/RIT
SET
 for 1 sec. twice to enter 
the set mode.
w  Rotate [M-CH] to select “XFC.”
e  Rotate [DIAL] to select ON.
r  Push 
M-CH/RIT
SET
 to exit the set mode and return to 
normal operation.
w  While pushing and holding 
RIT
, the transmit fre-
quency is indicated. And rotate [DIAL] to set the 
transmit frequency.