ICOM 325300 Manual Do Utilizador

Página de 96
15
3
BATTERY CHARGING
N External DC power operation
An optional cigarette lighter cable (CP-12L or CP-19R; for 
12 V cigarette lighter socket) or external DC power cable 
(OPC-254L) can be used for external power operation. (We 
recommend the CP-19R when you want to connect a 12 V 
cigarette lighter socket.)
D Operating note
• Power supply voltage must be between 10.0–16.0 V  DC
(We recommend 11.0 V DC.) NEVER CONNECT OVER 16 
V DC
 directly into the [DC IN] jack of the transceiver.
• BE SURE to use CP-12LCP-19R or OPC-254L when 
connecting a regulated 12 V DC power supply.
Use an external DC-DC converter to connect the transceiver 
through optional CP-12L, CP-19R or OPC-254L to a 24 V
DC power source.
• The voltage of the external power supply must be within 
10–16 V DC when using either CP-12L, CP-19R or OPC-
254L, otherwise, use the battery pack/battery case.
• Disconnect the power cable from the transceiver when 
not using it. Otherwise, the vehicle battery will become ex-
hausted.
• The power save function is deactivated automatically dur-
ing external DC power operation.
Transceiver
BP-264
• CP-12L (Optional)
• CP-19R (Optional)
• OPC-254L (Optional)
to cigarette lighter
socket (12 V DC)
to 11 V DC
(power supply)
White:
+
Black:
_
to
[DC IN]
NOTE: Up to 5 W (approx.) of maximum output power is 
available when using external DC power. However, when 
the supplied voltage exceeds 14 V, the built-in protection 
circuit activates to reduce the transmit output power to 
2.5 W (approx.).