ICOM 325300 Manual Do Utilizador

Página de 96
61
9
SET MODES
D Power save (P SAVE)
The power save function allows you conserve battery life by 
selecting the duty cycle of the receiver. Select the ratio of the 
power save time to the standby time.
(default: Auto)
• OFF
: Turns the function OFF.
• 2
: Sets the duty cycle to 1:2.
• 8
: Sets the duty cycle to 1:8.
• 16
: Sets the duty cycle to 1:16.
• 32
: Sets the duty cycle to 1:32.
• Auto
: Transceiver  sets “1:2” duty ratio when receiving no
sets “1:2” duty ratio when receiving no 
signal for 5 seconds, then it sets “1:16” after 60 sec-
onds has past.
62.5 msec.
60 sec.
125 msec.
1000 msec.
No signal
5 sec.
Circuit ON
Circuit OFF
NOTE: Power save function is disabled when connecting 
the external power supply (more than 10 V DC).
D Voltage indication (VOLT)
The power voltage, battery voltage or external power supply 
voltage, is displayed at power ON. This setting is selectable 
from ON or OFF. 
(default: On)
• OFF
: The power voltage indication is skipped.
• On
: The power voltage is displayed at power ON.
D DTMF speed (DTMF-S)
Select the desired DTMF transmission speed from 100 msec, 
200 msec, 300 msec, 500 msec.
(default: 100)
• 100
:  100 msec. interval; 5.0 characters per second
• 200
: 200 msec. interval; 2.5 characters per second
• 300
: 300 msec. interval; 1.6 characters per second
• 500
: 500 msec. interval; 1.0 character per second