ICOM IC-M602 Manual Do Utilizador

Página de 76
3
BASIC OPERATION
12
■ Optional voice scrambler operation
◊ Activating the scrambler
The optional voice scrambler provides private communica-
tions. In order to receive or send scrambled transmissions
you must first activate the scrambler function. To activate the
function, an optional UT-112 is necessary. See p. 45 for set-
ting the scrambler unit. Ask your dealer for details.
The scrambler function automatically turns OFF when
channel 16 or 70 is selected.
q Select an operating channel other than channel 16 and 70.
w Push [F] then [0 SCRM] to toggle an optional scrambler
function ON or OFF.
• “SCRAM” appears.
e To turn the scrambler function OFF, repeat step w.
• “SCRAM” disappears.
◊ Programming scrambler codes
There are 32 codes (1 to 32) available for programming when
the optional UT-112 is installed. In order to understand one
another, all transceivers in your group must have the same
scramble code. This function may not be available depend-
ing on dealer setting.
q Turn power OFF.
w While pushing [16•9], turn power ON to enter set mode.
e After the display appears, release [16•9].
r Rotate [CHANNEL] to select the “Scrambler Code,”
push [ENT].
t Rotate [CHANNEL] to select desired scrambler code.
y Push [ENT] to set and exit the scrambler code item.
u Rotare [CANNEL] to select “Exit,” then push [ENT] to
exit set mode.
Enter set mode
POWER
+
9
16
ENT
ENT
Select item
then push
Select code
then push
Scrambler Code
˘
9
˘
7
--Set Mode--
˘
5
˘
6
˘8
˘
<ENT˘OK>
˘Scan Type
˘
Scan Timer
--Set Mode--
˘
Internal Speaker
˘
Contrast
˘
Beep
˘
Dual/Tri COMMANDMIC
˘
WX Alert
˘
Internal Speaker
˘
Contrast
--Set Mode--
˘Scrambler Code
˘
Exit
˘
Scrambler Type
˘
Foghorn Frequency
˘
RF Attenuator
[Example]: Programming scrambler code 8.