Shanghai Senben Lighting Technology Company 1105B6105B100 Manual Do Utilizador

Página de 3
  2 / 3 
 
 
11. Bulk type terminals make wiring reliable. 
12. The  light  can  be  installed  in  pipe  suspending  type,  ceiling  type,  wall  mounting  type,  guard 
pole type and flange pole type. See Figure 2 for installation instructions. 
 
3. Directions   
1.  In order to ensure the safety service of this Ex light, it shall be installed and maintained by 
trained personnel. Unauthorized people shall not open or disassembly the fasteners. 
2.  Since  polyester  transparent  cover  is  adopted,  there  is  a  waning  label:  Warning - Potential 
electrostatic charge - see Instruction Manual. The installation hight shall no less than 2.5m, 
user  shall  pay  attention  to  the  electrostatic  charge.  Avoid  ignition  risks  caused  by  normal 
service,  maintenance  and  cleaning;  do  not  touch  or  wipe  the  light  in  hazardous  areas. 
Necessary replacement, wiping and touch shall be carried out in non-hazardous area. 
3.  Installation  and  maintenance  procedures  shall  meet  associate  national  standards,  do  not 
operate  when  energized.  Do  not  open  when  energized  in  maintenance  or  replacement  and 
waiting for the illuminant to cooldown. 
4.  There must be a designated person to in charge of the maintenance work specially. 
a)  Special operational platform, ladder, safety belt and other necessary equipment shall be 
equipped to ensure personnel safety; 
b)  Inspect  the  light  periodically,  any  component  damage,  loss  shall  be  fixed  in  time; 
replace  the  aged  sealing  ring  or  other  plastic  part  to  ensure  the  explosion  proof 
performance. 
5.  Take care of the disassembled components to avoid loss or drop from high cause casualties. 
6.  Aged  sealing  rings  shall  be  replaced  by  one  of  the  same  specifications  to  ensure  the 
explosion proof performance. See Figure 12 for the detailed specifications. 
7.  Ensure Do not open when energized is strictly followed, cut off the power if the top cover is 
required to open in maintenance. 
8.  The internal and external earthing shall be reliable. 
9.  Unauthorized personnel is not allowed to disassemble the light. 
10.  Do not replace the components or change the structure of the qualified product at will, these 
activities may affect the explosion proof performance. 
11.  Protect the flameproof joint from damage or rust, lubricate with 204-1 anti-rust oil. 
12.  DO NOT OPEN WHEN ENERGIZED! 
13.  Check the voltage of the power, make sure that it is in the service range of the light to avoid 
the light being damaged by improper voltage.