Shanghai Senben Lighting Technology Company 1106610665 Manual Do Utilizador

Página de 3
User manual 
FCC ID: 2AA551106610665 
For Model: SBD1106-YQL65; 
SBF6106-YQL65; 
1. use 
Shanghai Senben Lighting Technology Incorporated Company’s SBD1106 SBF6106 Maintenance-free, 
Energy-saving,Waterproof, Dustproof and Corrosion-proof Factory Lamp, the light source is induction lamp, and 
has the high Luminous Efficiency, longer lifespan etc features, the luminaire adopts the integrated structure, 
aluminum alloy die-casted ballast box and incoming line cover with the surface painted with polyester powder, 
This product is applicable for the common lighting or emergency lighting of such indoor and outdoor place with 
mech dust or damp such as factory ,airport,tunnel,especially power plant and its boiler unit,iron& steel plant and 
so on. 
2.Electrical parameters: 
1. 
Rated Vol.:
120VAC 60Hz
 
2. 
Illuminant: Electromagnetic   
induction illuminant 
3. 
Power: 65w or 80w 
4. 
Ex marking:   
Ex deⅡCT4 Gb (65W) 
Ex deⅡCT3 Gb (80W) 
DIP A20 TA, T6 
5. 
IP 
code: IP66 
6. 
Corrosion-proof grade: WF2 
7. 
Applicable cable outer diameter: 
φ 9~12.5mm 
8. 
Outline and installation size see Figure 1 
 
3. Directions   
1. 
In order to ensure the safety  service of this Ex light, it shall  be installed and maintained by trained 
personnel. Unauthorized people shall not open or disassembly the fasteners. 
2. 
Since polyester transparent cover is adopted, there is a waning label: Warning - Potential electrostatic 
charge  -  see  Instruction  Manual
.  The  installation  hight  shall  no  less  than  2.5m,  user  shall  pay 
attention to the electrostatic charge. Avoid ignition risks caused by normal service, maintenance and 
cleaning; do not touch or wipe the light in hazardous areas. Necessary replacement, wiping and touch 
shall be carried out in non-hazardous area. 
3. 
Installation and maintenance procedures shall meet associate national standards, do not operate when 
energized. Do not open when energized in maintenance or replacement and waiting for the illuminant 
to cooldown. 
4. 
There must be a designated person to in charge of the maintenance work specially. 
a) 
Special  operational  platform,  ladder,  safety  belt  and  other  necessary  equipment  shall  be 
equipped to ensure personnel safety; 
b) 
Inspect  the  light  periodically,  any  component  damage,  loss  shall  be  fixed  in  time;  replace  the 
aged sealing ring or other plastic part to ensure the explosion proof performance. 
Figure1 
 
 
 
Picture 1 
 
Type A 