Appendix C – RF cable loss values for lab 
testing 
 
The DUTs prepared for the certification have been calibrated at the M2 antenna port, hence the new 
small grey cable which is not seen, as the samples have been closed need to be added as extra loss. 
 
This cable is identified as Digikey 931-1193-ND
 
Please see below
 
the datasheet, which shows a graph of the insertion loss of the cable. 
 
Cable loss values 
 
To ease process, please use the table below, either R&S platform or Anritsu platform is being used for 
testing. 
 
Frequency(GHz)  Cable Loss(dB) 
0.00 
0.00 
0.10 
0.10 
0.30 
0.20 
0.50 
0.39 
0.75 
0.38 
0.78 
0.36 
1.71 
0.55 
1.76 
0.55 
2.11 
0.61 
2.16 
0.61 
3.00 
0.83 
3.10 
0.74 
 
Cable datasheet 
The datasheet of the cables is available 
under 
Insertion loss data extract below 