Sequans Communications US60L Manual Do Utilizador

Página de 18
o
 
By default it should set to ATT testing (See “Colibri_4G-
EZ_LR4130_ATCommands_ReferenceManual_Rev1” for detailed AT command 
settings – the Troubleshooting guide can help you understand where to type in AT 
instructions on the DM tool) 
  AT+SQNCTM? 
  AT+SQNAUTOCONNECT? 
  AT+CEMODE? 
o
 
You should read 
  > AT+SQNCTM? 
  > SQNCTM: ATT 
  > AT+ SQNAUTOCONNECT? 
  > 1 
  > AT+ CEMODE? 
  > +CEMODE: 2 
o
 
If the configuration is not as expected, using following commands, to set the correct 
one 
  AT+SQNCTM=”ATT” 
  AT^RESET 
•  Wait till reboot is completed 
  AT+SQNAUTOCONNECT=1,1 
  AT^RESET 
•  Wait till reboot is completed 
  AT+CEMODE=2 
  AT^RESET 
•  Wait till reboot is completed 
3.1  Typical lab test setup overview  
 
  
 
 
 
 
 
 
 
 
 
Above is a diagram of the normal setting of Conformance test for a US60L-based device in FFF 
mode. The tester includes a network simulator and a host PC controller with automation manager 
(Green part). 
The host PC is connected to the DUT using USB interface. 
 
Tester 
Network 
Simulator  
 
 
Board  
 
 
ECM 
(port 4664) 
Host CTRL PC 
Manual AT command 
or 
Automation manager 
 
LTE RF 
ACM 
 
U
S
U
S
SEQUANS Communications Confidential and Proprietary 
 
US60L_Setup_Instruction_R01 
5/18