Ever Sinline Rack 2000VA/1350W W/SL00RM-002K00/00 Manual Do Utilizador

Códigos do produto
W/SL00RM-002K00/00
Página de 3
1600VA/1040W
2000VA/1350W
~160 - 264V (~145 - 280V) ± 2%
45 - 55Hz  1Hz
± 
~184 - 264V (~167 - 280V) 
 
± 2%
same as input 
<3 ms
sinus
~230V ± 5%
50Hz   1Hz
±
LC
Electronic
Electronic
0 ms
3 x 12V 5Ah
6 x IEC 320 C13
+ / -
RS 232
PowerSoft Personal
Noise filter RFI-EMI / varistor damper
88 x 500 x 320
20kg
sound and LED
Rooms with low level of pollution
o
+10 C - +35 C / 
o
o
o
0 C - +45 C
up to 1000m
20 - 80% / 20 - 95% (without condensation)
line-interactive (VI)
Rack 19” 3U
SINLINE 1200
Rack
SINLINE 1600 
Rack
SINLINE 2000
Rack
1200VA/780W
2 x 12V 7Ah
7h
132 x 500 x 400
800, 1200, 1600, 2000, 3000
SINLINE Rack
SINLINE 3000
Rack
3000VA/1950W
4 x 12V 5Ah
4 x 12V 7Ah
5h
5h
7h
25kg
32,5kg
35kg
Circuit breaker
Rack 19” 2U
MODEL
Support time (100/80/50% Pmax)
Accumulator capacity
3)
UPS charging time 
1) For normal operation of the battery back-up the load connected to its output should not exceed 80% of value indicated in the table. Reserve power is essential to ensure continuous operation of 
connected devices in case of momentary rushes in load current.
2) User may modify the switching thresholds within the range provided. Default setting is provided in parentheses.
3) After discharging the UPS with 0.8 Pmax power – charging the battery to 90% capacity.
4) Continued exposure of the battery back-up to the ambient temperature exceeding +25°C will shorten the life of batteries.
5) If the altitude above sea level increases beyond the provided limit the permitted load power of the batter back-up decreases.
W
a
rn
in
g
T
h
e
 m
a
n
u
fa
c
tu
re
re
s
e
rv
e
s
 t
h
e
 r
ig
h
to
 c
h
a
n
g
e
 t
h
e
 a
b
o
v
e
m
e
n
ti
o
n
e
d
 p
a
ra
m
e
te
rs
 w
it
h
o
u
n
o
ti
c
e
.
Output power (apparent/active)
1)
 
Input voltage 
2)
Range of output voltage 
2)
Shape of output voltage
BACK-UP (BATTERY) OPERATION MODE
Output voltage
Shape of output voltage
Switching thresholds: UPS – mains 
2)
Filtering of output voltage
Shorting safeguard
Frequency of output voltage
Frequency of input voltage
MAINS OPERATION MODE
Switching thresholds: mains - UPS 
2)
Time to switch to UPS
Overload protection
Filtering of output voltage
Technology
Case type
Switching time: UPS – mains
ENVIRONMENTAL PARAMETERS
Software
Number and type of outlet sockets
Telephone line / LAN filter
Communication interface
Signalling
Working environment
 
Operating / storage temperature 
4
)
 
Altitude above sea level
 
5
)
Relative humidity for operation / 
storage
EQUIPMENT
Overcurrent protection
MECHANICAL PARAMETERS
Dimensions in [mm] (h x w x d)
Weight
4,5/6/10 min
4/5/9 min
4/5/8 min
3/4/8 min
~160V / 264V (~145V /~ 280V) 
 
± 2%
~165V /~ 259V (~150V / ~275V) ± 2%