Calculation the battery capacity
4 main factors impact the battery capacity/lifetime:
 Constant load: about 10µA for the current version Mode „Sleeping“ with
   periodically checking the radio. So 1 mAh is good for ca. 100 hours of „Sleeping“
 Pulse load: about 9mA for 0.2 seconds per measure, so 1 mAh is good for
    ca. 2000 measures
 Self discharge: about 10% after 10 years
 Temperature cycles: difficult to predict, could be up to 50% (worst case)
As a rough estimation: Theoretically 2400 mAh are good for  >25  years of  „Sleeping“ or
>4000000 measures (this is almost 500 years for 1 measure per hour), if no self discharge is
assumed. Practically we normally calculate only  with 1/3 of the capacity (the rest is for
spare):  For 1 measure per hour each year requires 5 mAh, with  the rest of 2400 mAh / 3 =
800 mAh still almost 8 years of operation should be possible. Hence we would recommend to
replace the battery with these settings  after 5 years or  later, if „temperature drops“ for cold
phases rises significantly.
Compliance informations (only for USA/Canada):
a) User Information according to FCC 15.21:
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment. 
b) Part 15 Statement according FCC 15.19/RSS Gen Issue 3 Sect. 7.1.3
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
LOG-PT1000: 
 FCC-ID 2AARE
0/:5 / IC Certification No IC: 11303A-0/:R10
LOG-PT1000-30: FCC-ID 2AARE
0/:R10 / IC Certification No IC: 11303A-0/:5
(Labels respecitvely assembled over battery screw cap)
Technical Shortform  LOG-PT1000(-30)  Wireless Temperature Data Logger
15.07.2013
Model: LOG-PT1000
 FCC-ID: 2AARE
0/:5
IC: 11303A-PT1K0CMR10
1cm
2.54cm
Model: LOG-PT1000-30
 FCC-ID: 2AAREPT1K30CMR10
IC: 11303A-PT1K30CMR10
1cm
2.54cm
Model: LOG-PT1000 
FCC-ID: 2AAREML5WR10 
IC: 11303A-ML5WR10
Model: LOG-PT1000-30 
FCC-ID: 2AAREML5WR10 
IC: 11303A-ML5WR10