Secuway Inc. IS5000 Manual Do Utilizador

Página de 33
 
 
 
23
23
 
To set the length of lockout time 
after number of incorrect ID input 
trials. Default setting is  30 sec 
(and the User  can set this to be  9~ 
60 sec) 
 
 
 
Fn342 (authorized to Master 
ID and Corresponding Group 
Manager ID) 
After the set number of times 
of incorrect trials, the IS 5000 
is locked out  for a pre-set 
amount of  time. 
 
Enter “1234567”, press “
” for 4 sec, Enter “342” press “
”,enter 
“Seconds  (9-60)”,press “
” 
Example: To change time  to 50 sec. 
 Enter “1234567”-> “
” for 4sec-> “342”-> “
”-> “ 50” for 50 
sec.-> “
”  
 
Disable or Enable  functions 341 
and  342. Default setting is 1 ( “0” 
disabled, “1” = enabled) 
 
 
Fn343 (authorized to Master 
ID and Corresponding Group 
Manager ID) 
 
Example:  To  disable function  341,342 
 Enter “1234567” -> “
” for 4 sec -> “ 343” -> “
” -> “0” for 
disable -> “
 
  
 
To set the interval time from 
opening by ID entered to re-locked. 
Default setting is 3 sec (able to set  
2~ 60 sec) 
 
 
Fn340 (authorized to Master 
ID and Corresponding Group 
Manager ID) 
  
Enter “1234567”, press “
” for 4sec-Enter “340” ,press “
”,Enter “ time 
sec” ,press “
” 
Example: To change the time to 15 sec 
Enter “1234567”-> “
” for 4 sec-> “340”-> “
”-> “15” for 15 
sec-> “
 
 
To set  the delay time  each key  input 
( if setting 5 sec, after first key entered, 
next key must entered within 5sec for 
the IS 5000 to stay active ) 
Default setting is 5 (able to set 2~ 9 
 
Fn344 (authorized to Master ID 
and Corresponding Group 
Manager ID) 
 
Enter “1234567”, press “
” for 4sec, enter “344” ,press “
”,Enter “seconds  (2-
9)”, press “
” 
Example: To change the time to 7 sec 
Enter “1234567”-> “
” for 4 sec-> “344”-> “
”-> “7” for 7 sec-> “