Shenzhen Minde Electronics Technology LTD. MS3390 Manual Do Utilizador

Página de 85
 
63 
 
FN1 substitution string setting: 
The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 
barcode, or a GS1 DataBar barcode can be substituted with a defined string.
 
Truncate leading G5 string setting: By setting, a defined leading character or string can be truncated. 
Also a single character can be un-defined.   
Repeat of a G5 character setting: While G5 is set as a single defined/un-defined character, G5 can also 
be set to be repeated. This setting is ignored when the truncate number is more than the barcode data 
characters. The option of “FF” for this setting is not active while the option of Truncate leading G5 string 
setting is “00”.   
Example: Truncate all leading zeros for all symbologies. 
Original code data  “0 0 0 1 2 3 4 5 6” 
Output code data 
“1 2 3 4 5 6” 
Steps: scan the following data in order. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Testing barcode: 
 
Truncate ending G6 string setting: By setting, a defined ending character or string can be truncated. Also 
a single character can be un-defined.   
Repeat of a G6 character setting: While G5 is set as a single defined/un-defined character, G6 can also 
be set to be repeated. This setting is ignored when the truncate number is more than the barcode data 
characters. The option of “FF” for this setting is not active while the option of Truncate ending G6 string 
setting is “00”. 
Single character C1/C2 replacement: By setting, a defined character in the data string can be replaced 
by another defined character. The C1 and C2 replacement are applied simultaneously. 
Example: Replace all the “A” character in a data string to be “B” character. 
Original code data  “1 2 3 A 5 A” 
Output code data 
“1 2 3 B 5 B” 
Steps: scan the following barcodes in order. The ASCII value for “A” is 41, and the ASCII value for “B” is 
42. 
 
 
 
 
 
 
 
Testing barcode: