AC International Corp. DWP-PCWRX Manual Do Utilizador

Página de 1
Wireless for Weighing Scale 
 
 
AD Transmitter               DA Receiver 
Accuracy 1/10,000 for any indicator       
Load cell    1 to 12 load cells 350
Ω   
Frequency bands 915.55MHz    
Power consumption 270 hours under weighing mode for one load cell 350
Ω, 29 months 
under sleeping mode( battery should be recharged every 5 months) 
Range 150 meters 
Working temperature   -10℃ to +60 ℃ 
 
 
 
 
 
 
 
 
LED indication           AD transmitter LED indication 
LED location 
Status 
Indication   
10Hz frequency flash 
Normal communication 
Communicate LED(left) 
0.3Hz frequency flash 
Sleeping status, 
communicate break 
flashing 
Battery voltage too low,   
need to recharge 
Battery voltage LED(middle)
 
Not flashing 
Battery voltage in good status 
        Red light on 
Charging status 
Green light on 
Battery is full   
Charger LED(right) 
Neither red or green light on
    Charger adapter is not connecting 
 
  DA receiver LED indication 
 
Changes or modifications not expressly approved by the party responsible for 
compliance could void the user's authority to operate the equipment. 
LED location 
Status 
Indication   
10Hz frequency flash 
Normal communication 
Communicate LED(left) 
Not flashing 
communicate break 
flashing 
Battery voltage in AD transmitter too low, 
need to recharge 
Battery voltage LED(middle)
 
Not flashing 
Battery voltage in good status 
Green light on 
Power supply status   
Power supplier LED(right) 
Green light off 
Power off status 
Transmitter 
Excitation 3.3v 
Input <12.9 mv 
Power 4V-5.5V 
Receiver 
Excitation 5-15V 
Output 3mV/V 
Load cell and Indicator wiring connection   
1 +Excitation  
 
2 +Signal 
 
 
   
-Signal   
   
4 -Excitation  
5   Shield