BW Broadcast Ltd TX300V2 Manual Do Utilizador

Página de 30
TX V2 FM Broadcast Transmitter  
 
FSK Keyer (Translators) 
16 
 
FSK Keyer (Translators) 
 V2 Transmitters support automatic station identification using frequency shift keying (FSK). FSK sends a user 
defined ID for the transmitter using Morse code by shifting the carrier frequency up by 12.5kHz at 20 words per 
minute. FSK parameters are set in the RF Settings menu: 
 
 
 
Set the FSK ID by scrolling through the characters using the control wheel (6), save each character by clicking 
the control wheel (6) and save the whole ID with the middle button (8). To cancel, press the back button (7). 
Audio Processing 
BW Broadcast’s range of award winning DSPX audio processors have become known for their features, 
performance and value for money. Integrated within all V2 Transmitters is the 4-band DSPXmini.  The 14 
available factory presets are selectable from either the front panel or the various remote control options. The 
processing is bypassed when using an external MPX input to allow for more control when using an external 
processor. To set a new preset navigate to: 
 
Audio settings → Processing Preset 
Each processing preset is loaded live as the user scrolls through the menu allowing for easy comparison 
between the different presets. 
A dedicated metering screen indicates the input levels, 4 band automatic gain control and limiters, along with 
audio level and MPX level meters. 
Remote Control 
V2 Transmitters offer many options for remote monitoring and control. All parameters available on the front panel 
are available remotely. 
• 
HTTP  
• 
RS232/Serial 
• 
Telnet 
• 
SNMP 
• 
Automatic Email Alerts 
Ethernet Settings 
The V2 Transmitters have a built in web server which can monitor and control all transmitter parameters remotely 
without the need to install any software. The unit can use either static or dynamic IP addressing. All Ethernet 
parameters are set in  
 
System → Ethernet 
Here, IP address, Subnet mask, Gateway and two DNS addresses can be assigned for static control, or DHCP 
can be enabled for dynamic IP control. 
Security 
Telnet and http connections are protected by a password. By default user name is admin and the password is 
pass. 
 
It is strongly recommended that the user changes this before connecting the device to an Ethernet connection. 
If a factory reset is performed on the device, the password will be reset to the default value of pass. The 
password is set in: 
 
 
System → Users 
TX V2 
► 
RF Settings 
► 
Audio Settings 
► 
Triggers 
► 
Alarms 
► 
System 
TX V2►RF Settings 
                       
Power                                                             25W 
MPX Source 
 
           Internal 
FSK                                                             1 Hour 
FSK ID 
 
             ABCD 
RF Mute on Silence 
 
                  1m