1.1 Product Technical Parameters and Features
1.1.1 Technical Parameters
1.
Using DC 12V~24V as working power,The main board max
working Current <500mA;
2.
Main board output port:32
3.
Working Environment:
Temperature:-10--60℃;
Relative Humidity:While Temperature(40±2)℃,Humidity
20%-93% No condensation;
4.
Storage Environment:
Temperature:-40--60℃;
Relative Humidity:While Temperature(40±2)℃,Humidity
20%-96% No condensation;
5.
The system using MiFare 1 card or CPU card , Operator
time:0.2~0.5 Second;
6.
RS485 external communication interface
Transfer format:9600bps,8,N,1;
7.
It is compatible to be used by keypad or password reader
1.1.2 Main Features
1.
Able to reserve 8192 blacklist records;
2.
The main board support control of 16 floors,the max control up to
112 floors if adding the floor expansion relay board;
3.
Each floor has 16 reception card permission;
4.
Each access floor is able to set up 40 pass code by user, but need to
be used with IC card which authorized with password permission.
5.
Able to save 30000 pcs offline message.
6.
When the elevator controller is off power or enters the fire fighting
state, it will automatically withdraw from the control of the
elevator and the elevator return back to its original state.