1.1 Product Technical Parameters and Features 
1.1.1 Technical Parameters   
1. 
Using  DC  12V~24V  as  working  power,The  main  board  max 
working Current <500mA; 
2. 
Main board output port:32 
3. 
Working Environment: 
        Temperature:-10--60℃; 
 
Relative  Humidity:While  Temperature(40±2)℃,Humidity 
20%-93% No condensation; 
4. 
Storage Environment: 
        Temperature:-40--60℃; 
Relative  Humidity:While  Temperature(40±2)℃,Humidity 
20%-96% No condensation; 
5. 
The  system  using  MiFare  1  card  or  CPU  card , Operator 
time:0.2~0.5 Second; 
6. 
RS485 external communication interface 
Transfer format:9600bps,8,N,1; 
7. 
It is compatible to be used by keypad or password reader 
1.1.2 Main Features 
1. 
Able to reserve 8192 blacklist records; 
2. 
The main board support control of 16 floors,the max control up to 
112 floors if adding the floor expansion relay board; 
3. 
Each floor has 16 reception card permission; 
4. 
Each access floor is able to set up 40 pass code by user, but need to 
be used with IC card which authorized with password permission. 
5. 
Able to save 30000 pcs offline message. 
6. 
When the elevator controller is off power or enters the fire fighting 
state,  it  will  automatically  withdraw  from  the  control  of  the 
elevator and the elevator return back to its original state.