The swivel support toolkit contains the following items:
 Mounting tools
The following screwdrivers are required for the installation:
• One small cross screwdriver
• One T10 Torx screwdriver
• One medium cross screwdriver
• One 0-1 flat head screwdriver
 Wire characteristics
To optimize the installation, Temaline recommends that you use the cable 
with smallest AWG allowed according to the tables below. If the power 
supply wire exceeds the AWG 20, Temaline strongly recommends that 
you terminate the wire with a smaller AWG.
Power supply wire
The Voyager device can be powered either with a 10V-30V DC 
power supply or 48V PoE. To determine the correct size of the power 
cable, see the table below.
Warning: 
Max voltage cable drop allowed must not exceed 0.8 VDC when 
the voltage is 12V. (Typical input current is 500mA.)
The tables below show the values for one reader. If more than one reader 
is connected to the same line, divide the distance by the number of the 
readers on the same line.
The following table lists examples of wire gauge and distance for a 12V 
and a 24V power supply.
Quantity
Description
1
Tamper switch with cable
1
Drilling template
3
Screws for Fisher plug S5V
3
Plastic plug Fisher S5C
2
Torx screws for reader closing