Features and benefits
EcoBreeze
Efficient and effective cooling
Right-sized cooling made possible by individual 
50 kW modules that can be grouped up to a 
maximum of 200 kW and 400 kW of sensible 
cooling per frame
Fully adaptable cooling via EC fan technology
Efficient and effective cooling via total internal 
isolation of the IT airstream from the outdoor 
ambient airstream
Regulatory compliance with recommendations 
and requirements for economization and 
efficiency (e.g., ASHRAE 90.1 in  
North America).
Adaptability
Ability to address any cooling requirement 
worldwide via multiple module and frame 
voltages/frequencies
Adaptability via the integration of multiple 
cooling options in one module footprint: indirect 
evaporative, air-to-air heat exchange, and 
proportional direct expansion
Ability to control redundancy from the frame 
down to the individual module level
Flexible and easy installation  
and servicing
Flexible and cost-effective deployment since  
the unit uses zero white space within the  
data center
Easy installation because of a single 
point of connection for water, power, and 
communications
Adaptable installation because it can be 
deployed with raised or non-raised floor 
applications
Safe and easy capacity expansion and 
servicing via individual isolation of air, power, 
and communications between the frame and 
modules
Environmentally friendly
No chemical treatment required due to an  
on-board water treatment system
Environmentally friendly because of zero ozone-
depleting proportional R410a refrigerant system
An innovative answer to cooling challenges
Today’s data centers face unprecedented cooling challenges brought on by high-density computing. 
Blade servers, for example, generate risky hot spots and therefore require a highly efficient, cost-effective 
cooling solution to safeguard availability while also streamlining cooling costs. Cooling also presents 
environmental challenges. With local, regional, and federal standards and regulations related to energy 
efficiency, now is the time for data centers to adopt economization (“free cooling”) as an innovative 
way to reduce energy consumption. EcoBreeze is the Schneider Electric™ answer to meeting the latest 
cooling and energy efficiency requirements facing today’s data centers. This innovative cooling approach 
employs a modular design for capacity, redundancy, and service flexibility. The efficiency of the system 
is rationalized in three forms of cooling to maximize localized climate conditions and ensure the most 
efficient and effective form of cooling year round. EcoBreeze employs the fully adaptable cooling of 
electronically commutated (EC) fan technology, along with an ozone-friendly proportional refrigerant 
circuit, making it one of the most efficient forms of cooling on the market today.