Hangzhou Hikvision Digital Technology Co. Ltd. MP5504 Manual Do Utilizador
Mobile Digital Video Recorder User Manual
46
Step 3 Check Motion Detection.
Step 4 Click Area Settings of Motion Detection.
Step 5 Edit area settings. For details, refer to 12.12 Configure Detection Area.
Step 6 Click OK.
Step 7 Set motion detection recording schedule. For details, refer to 8.2.5 Configure Schedule.
Recording type should be alarm, motion|alarm, or motion&alarm.
8.2.3 Configure Alarm Triggered Recording
Purpose:
Follow the procedure to configure alarm triggered recording.
Step 1 Go to Menu > Other Settings > Alarm In.
Figure 8-7 Alarm Input Settings
Step 2 Click Set of Trigger Record Channel to select the alarm triggered recording channel(s).
Step 3 Click OK.
Step 4 Enter the Record Settings interface to set alarm triggered recording schedule. Refer to
Chapter 3.1.2 for record settings. Recording type should be alarm, motion | alarm, or
motion & alarm.
motion & alarm.
8.2.4 Configure Alarm Terminal
Before you start:
Install an alarm terminal. For details, refer to alarm terminal user manual.
The RS-232 serial port should be used in the way of transparent channel and the baud
The RS-232 serial port should be used in the way of transparent channel and the baud
rate should be set as 9600.
Step 1 Go to Menu > Other Settings > Alarm Terminal.