Model PAS Proximity Alert System Manual 
Page 17 of 25 
 
 
 
Relay Outputs 
 
The PAS-300 Power Junction Box has isolated relay outputs which are controlled according to  this screen setup. The 
closest object of any given type can assert any one of four different relay outputs. 
Tap any box to cycle through the five available options; 1, 2, 3, 4 and -. The dash means no relay output is asserted. 
Take the above screenshot as an example setup and assume there’s an Obstacle tag in the Mid zone and a Personnel 
tag in the Urgent zone. Two of the four relay outputs will be asserted; #2 (caused by the obstacle) and #4 (caused by 
the person). 
Passcode 
 
The various Setup screens and Diagnostic screens (not documented - for PBE use only) can be optionally protected by a 
passcode set by management to prevent modification by drivers. 
The passcode is a barrier and deterrent against drivers changing the setup of the system. PBE can override and cancel 
the passcode if required. 
By default, there is no passcode. Create one from the Change Passcode menu. Enter up to 16 digits. It will need to be 
entered a second time and if they match the passcode will be set. 
The passcode can be removed by just hitting enter twice without pressing any digits on the keypad. 
Note that setting a new passcode takes immediate effect. The F1 (Commit) and F5 (Discard) options used to leave setup 
are not relevant to the passcode. A passcode change cannot be discarded by F5. 
The Volume setup screen is, by default, the only menu not protected by the passcode, but this can be overridden by