GSI ELECTRONICS INC. EDGERFID Manual Do Utilizador

Página de 70
NOTICE
When using outdoor connections, mount the enclosure as close as possible to the
entry point of the wiring
IMPORTANT: The enclosures must be mounted near an AC Power with a disconnecting switch
IMPORTANT: Mount the system into a wooden or metal frame. Do not mount the system directly into the
drywall
NOTE: Install the enclosures (KP-8IN-1REL, TP-8IN-1REL) with the widest side of the screen placed hor-
izontally. Consult the wiring diagram concerning wire length restrictions between the enclosures.
NOTE: GSI Electronics recommends this kind of screw: Deck Screw for Wood
1. Place the enclosure at a height at which you can properly see the screen (KP-8IN-1REL, TP-8IN-
1REL).
2. Screw in the top left hand corner screw first.
3. Using a level, make sure the enclosure is straight, and then screw in the second screw on the lower
right hand corner.
4. Screw in the last two screws.
IMPORTANT: Leave a clearance as stated in Clearance around the system to allow the cover to
be removed for maintenance.
DC network or independent power supply connection
Two possible configurations are available: DC network (available on the Agri Alert 128 Touch network) or
the independent power supply. Depending on the DC network chosen, select the right wiring diagram for
the installation.
NOTICE
When tightening small terminal blocks, use a torque between 0.5N*m (4.43lbf*in) and
0.6 N*m (5.2lbf*in) to fasten a wire gauge from 16AWG to 18AWG.
Connecting the DC network
DC network is available from the AA128 Touch network.
The recommended installation is 16 AWG for the power supply wires at a length of 300 meters (1000
feet).
1. Locate the Automation terminal on the KP-8IN-1REL, TP-8IN-1REL, TR-2IN-1REL you want to
connect.
2. Connect the wires (24 or 28V and GND) from the KP-8IN-1REL, TP-8IN-1REL, TR-2IN-1REL. to the
network.
Consult the wiring diagrams to see the maximum cable distance according to the wire gauge.
IMPORTANT: Make sure to connect same identifications together and use the same network from one
side to the other.
IMPORTANT: In the AA128 Touch network, use the Automation network on the KP-8IN-1REL, TP-8IN-
1REL, TR-2IN-1REL.
18
895-00695