4. Reading out and programming the BIDI logger 
 
Our BIDI loggers are most versatile and can be adjusted to your personal requirements in 
terms  of  connection  time,  operating  mode,  transmission  interval,  transmitter  power,  and 
measurement period. The following parameters are set ex works: 
 
transmitter power:  
 
medium 
transmission interval: 
 
every 8 seconds
 
operating mode:   
 
7 days+/wake up 
connection time:   
 
Mon thru Sun, from 8am until 4pm 
 
 
start of measurement period:  2am 
 
 
amplification: 
 
 
high 
 
If you wish to program our BIDI logger, the logger needs to be set to communication mode 
beforehand (LED of the BIDI loggers must flash three times). There are three options on 
how to set the logger to communication mode: 
 
1.  Run the solenoid switch across the 
 symbol on the logger cap to set the BIDI logger 
to communication mode. 
 
2.  If  the BIDI logger has already been set to data transmission mode,  it can be set  to 
communication mode during the data transmission times. Please go to the main menu 
and  tap  on  Settings    Logger  utilities    Wake  up  to  set  the  BIDI  logger  to 
communication mode. 
 
3.  Or go to the main menu and tap on the menu Patrol Start (wait until the requested 
BIDI loggers is being received)  Settings. The tablet 
is now trying to “Wake up“ the 
selected BIDI logger and will then read it out. 
 
If the BIDI logger has been set to communication mode, please select in the main menu: 
 
1.1) 
 Settings, 
1.2) 
 Logger settings. 
 
If you have chosen option 1 or 2,  please note that  the BIDI  logger needs to be read out 
before it can be programmed
. If you tap on 
 
1.3) 
 Download, all listed BIDI loggers will be displayed. Select the desired BIDI logger 
and tap on 
1.4) 
 Apply. 
 
The selected BIDI logger will now be read out. 
 
 
 
NOTE:  
 
If the process is cancelled, please make sure the BIDI logger is 
 
 
 
 
still within radio range (+/- 8metres), that the logger is still set to 
 
 
 
 
communication  mode,    or  that  other  loggers   set  to   data 
 
 
 
 
transmission  mode  do  not  interfere  with  your  communication 
 
 
 
 
with the logger you have selected.