G ene ra tor re a dy
Runs MH or HPS la mps
High ef fic ien c y e lectro nic  balla st
No a co ustic r e a sona nc e
Lower ha rmonic  distrotion
High ou tput a nd improve d spectr um
Driver ef fic ien c y a t full power: 95-96%
Light-we ight a nd high ener gy-effic ien t.
Product Advantage
1.Introduction
Thank you for purchasing Efinity Electronic Ballast. Please review 
the following instructions to ensure you receive the best  perfor
mance. Each ballast uses a high temperature,resin-sealed compo
nent board for completely silent operation. Each unit is burned-in at 
the factory for approximately twelve hours to ensure maximum 
reliability.
E-Ballasts use a micro-processor similar to your home computer. 
This micro-processor allows the E-Ballast to run halide or sodium 
lamps. It is programmed for a "soft-start" and does not require an 
initial surge of power to light the lamp. This increase the lamp life 
and allows the end user to start multiple ballasts  ballasts at the 
same time without tripping breakers. To ensure safe operation, this 
Programmed for a "soft-start" and does not require an initial surge 
of power to light or missing lamp.In case of auto-shutoff, please 
disconnect from the power supply, remove the faulty lamp or check 
for wiring problems,wait for some minutes then restart your ballast.
Power cord with either NEMA 5-15 or NEMA 6-15 plug 
2.Controls, connections and indications 
Electronic ballast
Power output selector knob 
Output connector
IEC connector for power cord
USER MANUAL
A.
B.
C.
D.
E.
 
E
NEMA 5-15
NEMA 6-15
A
C
D
B
3.Product information
3.1.
 
Technical specifications
Version
1000W 120V/240V
600W 120V/240V
400W 120V/240V
3.8kg/8.82lb
3.8kg/8.82lb
3.8kg/8.82lb
Product weight
Dimensions (L*W*H)
394mmx110mm x73mm   308mmx110mm x73mm   281mmx110mm x73mm  
Temperature case
75 
℃ / 167℉
Temperature ambient
-20 ~ 40 
℃/ -4 ~ 104 ℉
Input  voltage +/-10%
120 V 
240 V 
Input current at 100%
8.60 A
4.30 A
Input power at 100%
1085 W 1055 W
120 V 
240 V 
5.60 A
2.80 A
655 W
645 W
120 V 
240 V 
3.59A
180 A
430 W
430W
Power factor
>0.99
Total Harmonic Distortion
< 10%
Frequency
50 - 60 Hz
Power inlet
IEC C14 
Power output settings 
50%/75%/100%
Ignition voltage:
5 kV
Inrush current:
Plug type:
≤37.5 Amps
Nema 5-15 Nema 6-15
≤50 Amps ≤37.5 Amps
Nema 5-15 Nema 6-15
≤50 Amps ≤37.5 Amps
Nema 5-15 Nema 6-15
≤50 Amps
HOT SPOT
3.3. HOT SPOT
Tcase max=60°C/140°F
3.4 Environment
USER MANUAL
394mm(1000W)
308mm(600W)
281mm(400W)
58.5mm
110mm
73mm
3.2. Main Dimension
The product is meant for use in climate rooms. The product may be used in damp 
environments. The product may not be used in wet environments or outdoors. The 
1000 W lamps function optimal when the ambient temperature is between -20 ~ 40℃ 
/ -4 ~ 104 ℉.   
 Model
H1-1000COB-GAA
H1-600COB-GAA
H1-400COB-GAA
7.Disclaimer
Any of following circumstances, will not be Efinity’s warranty:
1.Install the product without following the wiring diagram in this   
   manual and cause the product damage.
2.Damaged by human reason (like product is soaked in water) or 
   caused by not following the manual instructions.
3.Install or use the product without following the local laws and regula
   tions.
4.Cover the warrant logo personally, or the client /the third party tries 
   to maintain, repair, change the product and cause the damage.
5.Use of the environment does not meet the provisions of this manual.
6.Damaged by force majeure, like abnormal voltage, earthquake, 
   flood, fire, thunderstroke, transpor tation accidents, etc.
7.Man-made damage during carrying, transportation.
8.Damaged by unstable match from other company’ (not Efinity’s) 
   poor design or defective quality products.(like luminaire).
9.Beyond the warranty period
 
 
6.Warning
4.Wiring Diagram
-Ballast Case must be Grounded
Power surge,power outage,outage overloading may stress or 
damagethe lamp.As a safety feature,this Soft-Start technology 
also reduces ballast damage caused by a bulb failure.In case of 
an unexpected chut-off,please disconnect from the power supply,
remove the faultylamp,check for wiring problems,then plug-in the 
ballast power cord. 
5.Protections
1.End of Lamp Life(EOL)Protection
2.Short circuit protection
3.Open circuit protection
4.Ignition failure protection
5.Thermal protection
USER MANUAL
NOTE: This device complies with Part 18 of the FCC Rules.  
Changes or modifications not expressly approved by the 
party responsible for compliance could void the user's 
authority to operate the equipment.  This product may cause 
interference to radio equipment and should not be installed 
near maritime safety communications equipment or other 
critical navigation or communication equipment operating 
between 0.45–30 MHz. If this occurs, please change outlet 
or move the lamp far away from other appliance.  
(a) The interference potential of device or system:  
“Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference 
that may cause undesired operation.”  
(b) Simple measures that can be taken by the user 
to correct interference:  
“NOTE: This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by 
one or more of the following measures:  
- Reorient or relocate the receiving antenna.  
- Increase the separation between the equipment and receiver.  
- Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.  - Consult the 
dealer or an experienced radio/TV technician for help.”
Electronic Ballast
 for  400W/600W/1000W Metal Halide or High Pressure Sodium Lamps
USER MANUAL
USER MANUAL