The AgTech gateway is not properly configured (software, LoRa hub…): contact technical support. 
 
Bad radio connectivity 
Here are some hints that will help to improve the radio connectivity between the flow sensor and the 
AgTech gateway: 
 
Check that the LoRa antenna is properly connected to the AgTech gateway. 
 
Check that the LoRa antenna is installed in the outside, at least 15 feet above ground. 
 
Check that the distance between the flow sensor and the AgTech gateway is less than 1 mile. 
 
Keep the flow sensor away from any element that could disturb the radio signal: metallic pieces, 
vehicles, buildings, hills. 
 
Flow sensor is out of order (no LED light, no radio connectivity) 
Possible reasons are : 
 
Battery is down. 
 
Firmware bug. 
 
Electronics has been damaged by excessive operating temperatures. 
 
Electronics has been damaged by excessive humidity (sealing problem). 
In any of these cases, the flow sensor must be replaced by a new device.