Keystone Sales Group Inc. DM35LE Manual Do Utilizador
SAFETY NOTE
1, FCC NOTE:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
2, The manufacturer is not responsible for any radio or tv
interference caused by unauthorized modifications or
change to this equipment. Such modifications or change
could void the user’s authority to operate the
equipment.
3, This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interferen-
ce in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and
receiver.
-- Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV techni-
cian for help.
4, RF warning statement:
To maintain compliance with FCC’s RF exposure guideli-
nes, this equipment should be installed and operated
with a minimum distance of 20cm between the radiator
and your body.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
2, The manufacturer is not responsible for any radio or tv
interference caused by unauthorized modifications or
change to this equipment. Such modifications or change
could void the user’s authority to operate the
equipment.
3, This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interferen-
ce in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and
receiver.
-- Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV techni-
cian for help.
4, RF warning statement:
To maintain compliance with FCC’s RF exposure guideli-
nes, this equipment should be installed and operated
with a minimum distance of 20cm between the radiator
and your body.
DC Tubular Motor-
DM35LE-3/28
Specification
(A-02)
Parameter (More models and parameters are subject to the nameplate)
-10
55
Working
Temperature
Product introduction
One motor maximum can store 10 channels, over 10 channels, if still need add new
channels, it will be repeating covered last channel.
Functional features
:
Switch Direction
Built-in Receiver
Preferred Stop Position
Reset to Factor Mode
Memorized Setting
Quiet
Electronic Limit
Stall Protection
Jog & Tilt
Program Button
DC Power
Built-in Lithium Battery
Solar Charging
Motor installation
①
Driving tube must be close-fitting with crown and drive adapter.
②
Choose crown and drive adapter based on the driving tube.
Drive tube
Drive tube
②
Runner
①
Crown
③
Circlip
Stroke support
Tail insert bracket
Operation note
Please read the following precautions before use:
1. Before using for the first time,please charge,ensure a full charge before use.
2. Don’t operate motors when low voltage alarm:
2. Don’t operate motors when low voltage alarm:
①
When the power supply voltage is lower than 6.8V, the motor stops running,when the voltage
is more than 7.5V to restart.
②
When the power supply voltage is lower than 10V,every time the motor is running,start alarm
10 times,tip need to recharge.
3. Operating:
3. Operating:
①
The valid interval of the emitter button is 10s,the emitter will quit the set after 10s.
②
The motor will run or beep for hint,please do the next step after the hint.
4. Set limit position:
①
The up/down limit position can’t at the same position.
②
After limit setting,with power off and memory function.
③
Into the match-code status 2 minutes later,it will quit out the setting limits status
automatically.
④
It will delete every memory and restore the factory settings.
5. When the motor running without any operation, the maximum running time is 6
minutes,it will stop automatically.
6. If the emitter lost,new emitter can through the code way to add emitter quickly and retain the
limit.
&
READING
The motor has a built-in battery,using the charger
DC1653
(3.0Nm motor) to recharge.You can also use solar panels
DC1289A(B/C)
to charge;when the battery is low, insert the
charge,charger light shows red light.batteries is full when
the red light turns to green.
Signal line
Signal line
Charging instructions
Type
Rated Torque(N.m)
Rated Voltage(V)
Rated Current(A)
Emission Frequency(MHz)
Rated Speed(RPM)
DM35LE-3/28
3N.m
12V
433.925
MHz
28
RPM
2.2
A