ISSUED: 10-26-11  SHEET NO: 154-9015-1
Insert extension pipe (B) into adjuster tube (A)
and secure with one screw (C).
Adjust extension 
pipe to locate screw (C) into desired hook slot as 
shown in fi gure 2.1.
Insert second screw (C) through hole opposite 
of hook slot as shown in fi gure 2.2. Tighten both 
screws (C) using allen wrench (D).
2
• Adjuster tube (A) must be fully threaded (six 
or seven full turns) onto threaded fi tting in 
ceiling plate and then locked with 
M5 x 10 mm screw.
WARNING
Note: Adjustable extension column should only 
be connected to UL Listed Peerless ceiling plates 
with 1 1/2"-11.5 NPT threading.  See instruc-
tions provided with ceiling plate for additional 
assistance.
Thread adjuster tube (A) into bottom of threaded 
fi tting on ceiling plate (sold separately) as shown 
in fi gure 1.1.  Tighten adjuster tube so thread is 
securely engaged.
1
ceiling plate 
(sold separately)
HOOK
SLOTS
C
C
A
B
A
M5 x 10mm screw 
(not included)
fi g 1.1
fi g 1.2
fi g 2.1
fi g 2.2
Note: Only UL Listed Peerless components with 
1 1/2"-11.5 NPT threading should be connected 
to the adjustable extension column.
To connect additional component to adjustable 
extension column see instructions provided with 
your component.
1 1/2"-11.5 NPT 
threading
Align one small hole in the threaded fi tting of 
ceiling plate with slot of adjuster tube (A).  Insert 
and tighten one M5 x 10 mm screw (not included) 
through the hole of threaded fi tting and slot of 
adjuster tube (A) as shown in fi gure 1.2.