RJ45 Components
A
Connection Modules Cat.7
Telegärtner Karl Gärtner GmbH  •  Tel: +49-(0)7157 / 1 25-100  •  www.telegaertner.com
123
The VM 8-8 modules are employed as connections/extensions 
of commercially available, shielded/unshielded twisted-pair 
installation cables (Cat.5e/Cat.6/Cat.7) in the following ap-
plications: damaged cables, cable extensions, cable rerouting. 
When VM 8-8 modules are used, the cable segments in a 
structured wiring system do not need to be laid out again. This 
reduces the expenses for alterations and the overall costs to a 
minimum. Depending on the connection module type, up to 12 
incoming and 12 outgoing 8-wire cables can be permanently 
connected together without any significant reduction in the 
transmission characteristics or limitation of the maximum link 
lengths.
Performance Characteristics
•  connection via LSA Plus terminals on a common PCB
•  colour coding in acc. with EIA/TIA 568A and B
•  connection of 4-pair shielded/unshielded installation cables 
from AWG 24-22
•  pairs can be brought directly up to the terminal without 
untwisting the pairs
•  secure shielded contact using screw-on terminals directly 
on the PCB
•  variable cable feeds
•  separate cable strain relief using commercially 
 
available cable ties
•  tool-free installation of shielding cover made of 
 
stainless steel (19“ and on-wall mounted version)
•  surface mount (AP) type: incoming and outgoing cables 
 
in the same direction
•  surface mount, 19“, and basic (for loose connection) 
version: incoming and outgoing cables offset by 180 
degrees
•  ground connection option directly on the PCB (M4 screw)
•  EMC compatible in accordance with EN 50081-2 and 
50082-2
VM 8-8 Cat.7
6x VM 8-8 Cat.7
12x VM 8-8 Cat.7
Mechanical Characteristics
Material: housing
ABS non halogen, 
UL94 V1 black
sheet steel 1 mm, powder-laminated, light grey RAL 7035
Material: shield
copper conductive lacquer
stainless sheet steel
stainless sheet steel
Material: PCB
FR4
FR4
FR4
Material: PCB finish
Cu 35/35 chem. tinned
Cu 35/35 chem. tinned
Cu 35/35 chem. tinned
Material: cable ties
PA 6.6 UL94 V2
PA6.6 UL94 V2
PA 6.6 UL94 V2
LSA Plus: Cu conductor diameter
0,40 - 0,65 mm 
AWG 26/1 - AWG 22/1
0,40 - 0,65 mm 
AWG 26/1 - AWG 22/1
0,40 - 0,65 mm 
AWG 26/1 - AWG 22/1
LSA Plus: Wire diameter
0,7 - 1,7 mm
0,7 - 1,7 mm
0,7 - 1,7 mm
Climatic Characteristics
Tested / classified in accordance with DIN IEC 60068-1
25/070/21
25/070/21
25/070/21
Electrical Characteristics
Working current at 50° C
1 A
1 A
1 A
Voltage proof: contact-contact
≥ 1000 V=
≥ 1000 V=
≥ 1000 V=
Voltage proof: contact-shield
≥ 1500 V=
≥ 1500 V=
≥ 1500 V=
Transmission Chracteristics
default values
typ. values
default values
typ. values
default values
typ. values
Next: at 100 MHz
72.4 dB min.
82.3 dB
72,4 dB min.
82,3 dB
72,4 dB min.
82,3 dB
Next: at 250 MHz
66.4 dB min.
77.1 dB
66,4 dB min.
77,1 dB
66,4 dB min.
77,1 dB
Next: at 600 MHz
60.7 dB min.
67.1 dB
60,7 dB min.
67,1 dB
60,7 dB min.
67,1 dB
Return loss: at 100 MHz
24 dB min.
28.9 dB
24 dB min.
28,9 dB
24 dB min.
28,9 dB
Return loss: at 250 MHz
16 dB min.
18.7 dB
16 dB min.
18,7 dB
16 dB min.
18,7 dB
Return loss: at 600 MHz
8.4 dB min.
17.9 dB
8,4 dB min.
17,9 dB
8,4 dB min.
17,9 dB
Insertion loss: at 100 MHz
0.2 dB max.
0.05 dB
0,2 dB max.
0,05 dB
0,2 dB max.
0,05 dB
Insertion loss: at 250 MHz
0.32 dB max.
0.1 dB
0,32 dB max.
0,1 dB
0,32 dB max.
0,1 dB
Insertion loss: at 600 MHz
0.49 dB max.
0.3 dB
0,49 dB max.
0,3 dB
0,49 dB max.
0,3 dB
Contact Resistance
200 mΩ max.
< 10 mΩ
200 mΩ max.
< 10 mΩ
200 mΩ max.
< 10 mΩ
Cat.7
 Category 7 acc. to ISO/IEC 11801; EN 50173-1