Ilford 1649651 Manual Do Utilizador

Página de 6
 
FP4 Plus
 
  
 
 
 
 
 
 
 
50
stock/26ºC/78ºF
odak Duraflo RT
 
K
 
 
70
1+11/24ºC/75ºF
I FOTEC HC
 
L
 
54
 
84
 
45
65
40
55
1+1+2/26ºC/78ºF
1+1+5/26ºC/78ºF
ILFOTEC RT RAPID
 
 
I FOLAB FP40, roller transport and short leader machines (sec)
 
L
 
7
stock
 
Kodak Xtol
 
 
10
1/2
 
 
7
1/2
stock
 
Kodak T-Max RS
 
 
7
1+4
 
I FOTEC DD
 
L
 
11
1/2
 
8
1/2
Dip and dunk machines (min/24ºC/75ºF)
 
10
 
8
1/2
stock
 
Kodak Xtol
 
 
9
 
6
1+4
 
T
 
etenal Ultrafin Plus
 
9
 
14
 
7
11
1+10
 
1+20
 
Tetenal Ultrafin
 
12
 
9
7
1+10
 
Paterson Acutol
 
 
9
 
8
1+4
 
Kodak T-Max
 
 
 
 
15
23
10
17
stock
 
1+3
 
Kodak Microdol-X
 
 
6
 
12
 
4
1/2
9
6
B
 
Kodak HC-110
 
 
9
 
15
 
20
 
8
11
16
6
9
14
stock
 
1+1
 
1+3
 
Kodak D-76
 
13
 
20
 
9
15
1+25
 
1+50
 
Agfa Rodinal
 
 
9
 
6
stock
 
Agfa Refinal
 
 
6
 
4
stock
 
Acufine Acufine
 
 
Non-ILFORD developer
 
9
13
17
12
15
21
 
 
 
stock
 
1+1
 
1+3
 
PERCEPTOL
 
8
10
14
9
 
14
 
18
 
stock
 
1+1
 
1+3
 
MICROPHEN
 
10
 
15
 
 
stock
 
1+1
 
1+3
 
ID-11
 
8
1/2
11
20
6
1/2
8
17
4
8
12
5
 
9
 
 
6
8
1+9
 
1+19
 
1+29
 
ILFOTEC LC29
 
5
 
9
 
4
8
6
1+15
 
1+31
 
ILFOTEC HC
 
 
1+9
 
1+14
 
ILFOSOL S
 
 
7
1/2
 
 
6
1/2
9
1/2
4
1/2
7
1/2
10
12
 
8
1+4
 
I FOTEC DD-X
 
L
 
Spiral tank, deep tank, dip and dunk machines (min/20ºC/68ºF)
 
 
Meter setting
EI 50/18 
EI 125/22  EI 200/24
 
Dilution
 
ILFORD developer
 
For manual processing in spiral tanks and deep
tanks, the development times are based on
intermittent agitation. Where continuous agitation
 
is used for manual processing (as in a dish/tray or
with some types of developing tank), reduce these
times by up to 15%. For use in rotary processors
 
without a pre-rinse, reduce the spiral tank
 
development times by up to 15%. A pre-rinse is
 
not recommended as it can lead to uneven
 
processing.
 
35mm film, Rollfilm & Sheet film
 
DEVELOPMENT TIMES
 
The table gives development times for both manua
and machine processing FP4 Plus. These times wil
produce negatives of average contrast suitable for
printing in all enlargers. The development times
 
are intended as a guide and may be altered if a 
different result is needed.
 
Page 3 of 6