Adtran OC-3 CWDM SFP 1551nm 1442701PG5 Folheto

Códigos do produto
1442701PG5
Página de 2
Quad Fiber Remote SFP
COMPLIANCE
CAUTION: Electrostatic Discharge (ESD) can damage electronic modules. 
When handling modules, wear an antistatic discharge wrist 
strap to prevent damage to electronic components. Place 
modules in antistatic packing material when transporting or 
storing. When working on modules, always place them on an 
approved antistatic mat that is electrically grounded.
The Quad Fiber Remote SFP (P/N 1181307L8) is NRTL Listed to 
the applicable UL standards. The QDFRS meets or exceeds all 
the applicable requirements of NEBS, Telcordia GR-63-CORE, 
GR-78-CORE, and GR-1089-CORE.
The QDFRS is intended for deployment in Central Office type 
facilities, EEEs, EECs, and locations where the NEC applies
 
(ex. Customer Premises). Install the QDFRS in a restricted 
access location.
This device complies with Part 15 of the FCC rules. Operation is subject 
to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including 
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void 
the user's authority to operate this equipment.
CAUTION: Per GR-1089-CORE Section 9, the QDFRS does not have an 
internal DC connection between battery return and frame 
ground. The QDFRS can be installed in a DC-I (isolated) or
 
DC-C (common) installation. If the QDFRS is installed in a
 
DC-C (common) installation, the ampacity of the conductor 
connecting the equipment frame to the battery return conductor 
shall be equal to or greater than the ampacity of the associated 
battery return conductor.
NOTE: The DSX-1 ports are classified as Type 2 or 4, as defined in 
Appendix B of GR-1089-CORE Issue 4, and are suitable for 
connection to intra-building or unexposed wiring or cabling only. Do 
not metallically connect these ports to interfaces which connect to 
the Outside Plant (OSP) or to OSP wiring.
The DSX-1 ports are designed for use as intra-building interfaces 
only (Type 2 or Type 4 ports as described in GR-1089-CORE Issue 
4) and require isolation from exposed OSP cabling. The addition of 
Primary Protectors is not sufficient protection in order to connect 
these interfaces metallically to OSP wiring.
The OC-3 SFP port is optical and therefore is not classified as any 
type of port as defined in Appendix B of GR-1089-CORE Issue 4.
Current limiting protectors are not required.
The QDFRS is designed to operate with a nominal operating voltage 
of ±24 VDC or ±48 VDC and a minimum operating voltage of ±20 
VDC. The QDFRS will not be damaged by any steady state voltage 
below –56.7 VDC.
Configuration Code
Input
Output
Power Code (PC)
F
C
Telecommunication Code (TC)
Installation Code (IC)
A
Test Jack
The test jack has two modes (selected on the QDFCS):
Monitor Mode (non-intrusive): looks at a port in either direction
Intrusive Mode: “breaks” a port in either direction
MAINTENANCE
The QDFRS does not require routine hardware maintenance for normal 
operation. ADTRAN does not recommend that repairs be attempted in 
the field. Repair services may be obtained by returning the defective unit 
to ADTRAN.
Field support for software is provided through upgrade facilities. Refer to 
“Warranty” for further information.
PROVISIONING
Most provisioning is handled through remote management from the 
QDFCS. To directly access the QDFRS via the rear-panel DB-9 craft 
port, connect a VT100 (or compatible) terminal, set to:
9600 bps
8 data bits
No parity
No flow control
1 stop bit
Connection is directly to the QDF Main menu, with no login step. To 
traverse the menus, select the desired entry and press 
E
NTER
. To return 
to the previous menu, press 
E
SC
.
The QDFRS retains provisioning data in nonvolatile memory, in case of 
a loss of power.
Factory Defaults
On installation, the QDFRS is provisioned to factory default settings. 
The table below lists default values for key Provisioning options.
Option
Settings (Default in Bold)
DSX-1 Line Build Out
0-133 Feet; 133-266 Feet; 266-399 Feet; 
399-533 Feet; 533-655 Feet
DSX-1/DS1 Line Code
AMI; B8ZS
NIU Loopback
Disabled; Enabled
Loopback Timeout
None; 120 Min
DS1 TX Level
0 dB; –7.5 dB; –15 dB
Customer Loss Indicator
AIS; Loopback
Port Service State
In Service; Out of Service–Maintenance
Out of Service–Unassigned
For more information, refer to Total Access 3000/3010 QDFCS and QDFRS Installation and Maintenance 
Practice
 (P/N 61181307L8-5) available online at 
www.adtran.com
.
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not meet its 
published specifications or fails while in service. Warranty information can be found online at 
www.adtran.com/warranty
.
©2008 ADTRAN, Inc. All Rights Reserved.
PRICING AND AVAILABILITY
800.827.0807
TECHNICAL SUPPORT
800.726.8663
RETURN FOR REPAIR
256.963.8722
*61181307L8-22B*
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: SIM5110B_ _
Product P/N: 1181307L8
Issue Date: 0809
Document P/N: 61181307L8-22B
CRAFT
BATTERY 
FIBER 
OPTICS 
TX
RX
Complies with 21CFR, SubchapterJ, 
Parts 1010 and 1040. 
ADTRAN, Huntsville Al. 35814 USA 
24V-48V 
DS1
4
DS1
3
DS1
2
DS1
1